DR5033 DIGIBOOST
P 7
www.digikeijs.com
® R-Bus, B-Bus
are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz
Stand 2019-10-14
3.1 LocoNet® Variables (LNCV) Table
LNCV Descrip on
range
Default
LNCV Descrip on
range
Default
0
Loconet module address
1-9999
1
12
Wai2ng 2me
a@er
automa2c polarity reversal of the track
out before a short circuit is reported to the control unit.
(SePng in 3 millisecond steps.)
32-250
48
1
Firmware version (1000 = 1,000)
(Value can only be read)
-
-
13
Wai2ng 2me
before
polarity reversal or short-circuit signal.
(SePng in 3 millisecond steps.)
16-250
32
3
Configura2on LNCV
siehe unten
92
14
Op2onal switching address for polarity reversal of the out-
put
0-2048
0
6
Temperature of the H-bridge in degrees °C
(Value can only be read)
0-150
-
15
Polarity reversal ON for feedback A
0-2048
0
7
Current load in %
(Value can only be read)
0-100
-
16
Polarity reversal ON for feedback B
0-2048
0
8
Turnout address for booster Individual switch-off
0-2048
0
17
Polarity reversal OFF for feedback D
0-2048
0
11
Wai2ng 2me
un l restart
aIer short circuit.
The default value corresponds to approx. one 3/4 second
(750 ms). (SePng is done in three millisecond steps.)
64-30000
244
18
Polarity reversal OFF for feedback E
0-2048
0
Bit
Wert Descrip on
Default
Bit
Wert Descrip on
Default
0
0
Not used
0
4
0
Booster does not send a special LocoNet® message in case of
short-circuit shutdown.
16
1
Not used
16
Booster sends a LocoNet® message in case of a short circuit so
that the central unit can display which booster has been
switched off.
1
0
Track Out
ac2ve as soon as an input signal is detected.
0
5
0
Track Out ac2ve without output polarity reversal (blue LED off)
0
2
Track Out
ac2ve as soon as the GO/Stop bu3on of the control
unit is pressed or the connected switching address (LNCV 8) is
switched to green.
32
Track Out ac2ve Output reversed polarity (blue LED on)
2
0
Booster does not send 'GPON/GPOFF' L.NET report on short
circuit.
Automa c
short-circuit repair
is enabled.
4
6
0
Automa2c polarity reversal off
64
4
Booster sends 'GPON/GPOFF' L.NET report to headquarters. The
central
determines when the track out is switched on again.
64
Automa2c polarity reversal on
3
0
Not used
8
7
0
Not used
0
8
Not used
128
Not used
3.2 Descrip on Configura on LNCV 3
With the LNCV 3 the behaviour (short-circuit behaviour, start behaviour, automa2c reverse polarity, etc.) of the booster can be adapted.