DR4088CS / GND / OPTO
2021
-
08
-
11
P 4
www.digikeijs.com
® R
-
Bus, B
-
Bus
are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS
-
Bus is a trademark registered in the name of Lenz
2.0 Product overview
2.1 General product information
The DR4088xx is a feedback module that can be connected to the central unit via the S88(N)®.
The DR4088
-
xx has 16 feedback inputs.
The DR4088xx is available as CS version (current sensor 2
-
wire track), as OPTO version (connection of reed contacts, 3
-
wire track signal to track ground) and as
GND version (3
-
wire track).
2.2 Technical specifications
The connection terminals of the 16 feedback units are designed for a cross
-
section of 0.5mm², the two terminals for "C" are designed for a cross
-
section of
0.75mm².
Number of
inputs
Suitable
for
Minimum load for safe
reporting
Max. load per
contact Load
per contact
Max. load per con-
tact Load capacity
per contact for
max. 100 ms
Peak load for 8 feedbacks at
"C" total.
DR4088CS
2 x 8
2 conductors
2 mA
2 A
5 A
6 A an
„
C
“
DR4088OPTO
2 x 8
3 conductors
when using the
DR50xx
-
-
-
DR4088GND
2 x 8
3 conductors
Important
! DR4088GND 3
-
wire operation:
Due to the H
-
bridge (track output) in the DR50xx, feedback devices in the DR4088GND version must not be used against track ground, as
is usually the case with 3
-
wire tracks. This inevitably leads to the destruction of the DR50xx.
If a 3
-
wire driver still wants to drive with the DR50xx and report back against track ground, the DR4088OPTO
can be used.