Digikeijs DR 4088 series Скачать руководство пользователя страница 1

DR4088CS / GND / OPTO  

2021

-

08

-

11

 

P 1

 

www.digikeijs.com

 

® R

-

Bus, B

-

Bus

 

are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS

-

Bus is a trademark registered in the name of Lenz 

DR 4088xx

 

Instruction manual

 

 

(2021

-

08

-

11)

 

© Copyright 2005 –

 2018 

digikeijs, the Netherlands. All 

rights reserved. No information, images or any part of 

this document may be copied without the prior written 

permission of Digikeijs.

 

Содержание DR 4088 series

Страница 1: ... of Modelleisenbahn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz DR 4088xx Instruction manual 2021 08 11 Copyright 2005 2018 digikeijs the Netherlands All rights reserved No information images or any part of this document may be copied without the prior written permission of Digikeijs ...

Страница 2: ...erview 4 2 1 General product information 4 2 2 Technical Specifications 4 2 3 Hardware Overview 5 3 0 Programming 6 3 1 DR4088xx programming start address in the DR500xx assigned 6 3 2 DR4088xx reset 7 4 0 Connection examples 7 4 1 Feedback modules DR4088CS 2 wire track 8 4 2 Feedback modules DR4088CS and DR5033 Booster 2 wire track 9 4 2 Feedback modules DR4088OPTO Hall sensors 3 wire track 10 4 ...

Страница 3: ...y ATTENTION The warranty is void if the housing of the product is opened 1 3 Legal information Printing errors and mistakes technical or other changes as well as changes in the availability of individual products are expressly reserved Data and illustrations are non binding All changes to hardware firmware and software are reserved We reserve the right to change the design of the product the softw...

Страница 4: ...back units are designed for a cross section of 0 5mm the two terminals for C are designed for a cross section of 0 75mm Number of inputs Suitable for Minimum load for safe reporting Max load per contact Load per contact Max load per con tact Load capacity per contact for max 100 ms Peak load for 8 feedbacks at C total DR4088CS 2 x 8 2 conductors 2 mA 2 A 5 A 6 A an C DR4088OPTO 2 x 8 3 conductors ...

Страница 5: ...w 1 Connection feedback 1 to 8 2 Common connection C for the right or left detector group 3 Connection feedback 9 bis16 4 S88 OUT connection continue to the next DR4088xx 5 S88 OUT connection to central or previous DR4088xx 6 red LED flashing during load or activity at S88N connection 7 S88N IN connector standard RJ45 patch cable continue to next DR4088xx 8 S88 IN connection continue to the next D...

Страница 6: ...is possible because the S88 N bus is not desig ned for individual address assignment The S88 N can only be set up as a bus line network This always means from 1 feedback to 2 feedback etc 3 1 Programming DR4088xx Assign start address in DR50xx The S88 N bus system does not provide programming in the actual sense It only has to be defined in the central with which address the S88 N bus starts and h...

Страница 7: ...et DR4088xx Important The DR4088xx The DR4088xx has no function for resetting to factory settings Since no settings or functions are stored in the feedback module this is not necessary Important DR4088GND 3 wire operation Due to the H bridge track output in the DR50xx feedback devices in the DR4088GND version must not be used against track ground as is usu ally the case with 3 wire tracks This ine...

Страница 8: ...leisenbahn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz DR5000 in conjunction with S88N feedback modules The ext88N connector of the DR5000 is a compatible S88N bus In this example the feedback modules DR4088CS current sensors are used These feed back modules are connected to the DR5000 and to each other with normal RJ45 cables A maximum of 16 S88N modules with 16 inputs...

Страница 9: ...eisenbahn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz R Bus B Bus are trademarks which are registered in the name of Modelleisenbahn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz 4 2 Feedback modules DR4088CS and DR5033 Booster 2 wire track Both sides track isolation ...

Страница 10: ...odelleisenbahn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz power supply 4 3 Feedback modules DR4088OPTO Hall sensors 3 wire track Light barrier Hall sensors or the like positive switching PNP 5V 20V DC AC Feedback Track mass switch track reed contact DR4088OPTO More DR4088xx feedback unit ...

Страница 11: ...Modelleisenbahn GmbH XpressNet and RS Bus is a trademark registered in the name of Lenz 4 4 Feedback modules DR4088OPTO switch track 2 wire track More DR4088xx feedback unit switch track Light barrier Hall sensors or the like positive switching PNP power supply 5V 20V DC AC reed contact push Botton Switch DR4088OPTO ...

Страница 12: ...s Feedback Track mass switch track reed contact Track Out Central S88 N Zentrale Important DR4088GND 3 wire operation Due to the H bridge track output in the DR50xx feedback devices in the DR4088GND version must not be used against track ground as is usually the case with 3 wire tracks This inevitably leads to the destruction of the DR50xx If a 3 wire driver still wants to drive with the DR50xx an...