PCX-IP LW881e, PCX-IP LW1221e
User’s manual
To configure the Livewire Destinations, click on “Destinations”. The following page is displayed.
From this page, you can :
●
Give a name to each local output to the Livewire node:
Name
(16 printable characters max). This can typically be the name
given to a channel of a recording application running on the PCXIP card (ex: PCXIP Rec1).
●
Select one of the available Livewire channels to be extracted and assign to the corresponding PCXIP input.
●
Set the
Type
for each selected livewire channel:
From source:
To source:
Configuration of GPIOs
Vu_meters
This page displays the vumeters of the signals available on the Livewire sources (typically audio coming from software players) and
destinations (typically Livewire channels to be recorded by software recorders).
Click on “Meters” to display the vumeters page.