background image

 

 

Page 2 

Digiflex Vision 64  Keyswitch wiring & programming                                            RDC_3138_E_TA 

 

E.g. 2:- Using a Zone: 

Choose any hardwired zone 1-8, Zn Dbl 9-16 can be programmed as a keyswitch. 

 

Menu 3-1-1  

Select option 13 (Key switch zone type). 

Menu 3-1-8 

Select option 3 (Inverted Seal) set to ‘Y’. 

Menu 3-4-1 

Select option 05 (Pulse all On/Off) . 
 
If using zone double (zn 9-16) the zone 1-8 on the same terminal should be an Entry/Exit zone type.

 

 

 

Zones 1 

– 8 use 3k3 resistors  

 

Zones 9 

– 16 use 6k8 resistors 

 

 
 
 
 
 
 
Exiting Program Mode: 
 

 

Press and hold the Menu button for 2sec. 

 

Alternatively you can select Exit and press OK from any menu levels. 

 

Zn Doubling Table 

10 

11 

12 

13 

14 

15 

16 

 

 

Отзывы: