http://bit.ly/SmartRF
RF112IRG Rev1.6 P/N DF2382
RF112 Device Specifications
Parameter
Value
Input Types
Supported
Single EOL, Alarm+Tamper,
Dry Contact or Pulse Counting
(Clicker input)
Operating Temp -10°C to +49°C
Humidity 0% - 93% Non-condensing
Battery 3V CR123A Lithium
Battery Life Up to 2 years
Frequency 433.42MHz
RF Modulation FSK
Data Rate 25kbps
Data Encoding Manchester
Approvals RCM (ANZ), CE (Europe)
Using Side Reed SW
=
Alarm to N/C
Metal Surface
Timber Surface
M
Magnet
In
High
Position
X
11mm
23mm
Y
+14mm
to -11mm
+16mm to
-12mm
Z
20mm
27mm
M
Magnet
In
Low
Position
X
7mm
23mm
Y
+12mm
to -10mm
+15mm to
-13mm
Z
26mm
35mm
Z
X
Y-
Y+
Using Side Reed SW
=
N/C to Alarm
Metal Surface
Timber Surface
M
Magnet
In
High
Position
X
11.5mm
24mm
Y
+14 mm,
-11mm
+16mm,
-13mm
Z
21mm
28mm
M
Magnet
In
Low
Position
X
7.5mm
23.5mm
Y
+12mm,
-10mm
+15mm,
-13mm
Z
27mm
36mm
Z
X
Y-
Y+
Using End Reed SW
=
N/C to Alarm
Metal Surface
Timber Surface
M
Magnet
In
High
Position
X
-8mm
-22mm
Y
+11 mm,
-11mm
+15mm,
-14mm
Z
18.5mm
26.5mm
M
Magnet
In
Low
Position
X
-4.5mm
-22mm
Y
+8.5mm,
-9.5mm
+15mm,
-14mm
Z
24.5mm
35.5mm
Z
X
Y-
Y+
9
10
Z
X
Y-
Y+
Using End Reed SW
=
Alarm to N/C
Metal Surface
Timber Surface
M
Magnet
In
High
Position
X
8mm
21mm
Y
+11 mm
to -11mm
+15mm to
-14mm
Z
18mm
26mm
M
Magnet
In
Low
Position
X
4mm
21mm
Y
+8mm to
-9mm
+15mm
to -14mm
Z
24mm
35mm
LED Indicator
MA
GNET
MA
GNET
MA
GNET
MA
GNET
High Magnet Position
M
Low Magnet Position
M
For best performance install the magnet as close as pos-
sible to the RF112, and align the centre of the magnet
with the alignment mark on the RF112 housing. Use
the tables in section 9 and 10 as a guide to placement
performance in your installation.
11
RF112
Magnet Alignment Marks
Side Magnet
End M
agnet
LED Indicator
Magnet Installation
Magnet Placement Guide -Side Reed
Magnet Placement Guide -End Reed