Installer  

Reference Guide 

CM430S 

RS485 LAN To Ethernet 

Converter Module

Rev 1.2

®

Содержание CM430S

Страница 1: ...Installer Reference Guide CM430S RS485 LAN To Ethernet Converter Module Rev 1 2 ...

Страница 2: ...ue Blue Connection Established Green Ethernet Cable connected Power RED Off Power OFF On Power ON Table 2 LED Indicators Initial Setup Using a stand alone computer your PC must have an Ethernet port you can connect your computer directly to the CM430S using a crossover Ethernet cable Otherwise connect both the computer and CM430S using straight through Ethernet cable to a hub or switch Ensure comp...

Страница 3: ...your browser and enter 192 168 1 200 Factory set and press Enter If the unit is reset by the user then its default address will be 192 168 1 254 A window will be displayed prompting you to enter the password default 123456 After entering the password the web browser page will be displayed Figure 1 Point to Point Location 1 Figure 2 Point to Point Location 2 ...

Страница 4: ... Point Configuration A pair of CM430S modules is required for each link as shown below Remote locations will require a local power supply wih backup battery to maintain connectivity during power outages A CM720 1 amp or CM723 5 amp power supply module would be suitable for this task Ethernet GND 12V LAN A LAN A LAN B LAN B IN OUT Not Used Reset Protect Type Static IP IP Address 192168 1 6 Connecti...

Страница 5: ...on will need to go through a LAN switch that has a backup power supply Each Remote location will require a local power supply with backup battery to maintain connectivity during power outages A CM720 1 amp or CM723 5 amp power supply module would be suitable for this task Figure 4 Sample Star Configuration Location 1 Figure 5 Sample Star Configuration Locations 2 17 ...

Страница 6: ...c IP IP Address 192168 1 5 Connection Mode TCP Server Location 1 RS232 Not Used GND 12V LAN A LAN A LAN B LAN B IN OUT Module LAN B A Not Used Reset Protect RS232 GND 12V LAN A LAN A LAN B LAN B IN OUT Module LAN B A Not Used Reset Protect RS232 Ethernet GND 12V LAN A LAN A LAN B LAN B IN OUT PANEL LAN B A Not Used Reset Protect RS232 Module LAN B A Not Used Local Power Supply Battery Local Power ...

Страница 7: ...CM430S Reset The CM430S modules can be reset whilst powered up by using a thin screwdriver and sliding the Reset switch from OFF to ON position then after 2 3 seconds back to the OFF position This will reset the device IP to 192 168 1 254 CM430S Specifications Part Number CM430S RS485 LAN To Ethernet Module Supporting Star Configuration Operating Voltage 10 5V D C 14 5V D C 150mA Max Module Connec...

Страница 8: ... 2002 2019 Digiflex Pty Ltd P N CM430SIRG DIGIFLEX PTY LTD Unit 5 8 Millennium Court Silverwater NSW 2128 AUSTRALIA Phone 612 97417000 Facsimile 612 97417042 www digiflex com au Our Vision Is Your Peace Of Mind ...