background image

26

6.5.1 Power connection

To disassemble the arm, it is necessary to cause a short-circuit between the GND and LIB
inputs, as shown below:

6.5.2 Assembling the arms

The arms are provided disassembled. To assemble them, follow the instructions provided
below:
The wrench used for assembling must be an Allen n.8 and the screw must be tightened to
the maximum to ensure good fixation. All three arms must be attached to the same
central upper point.

plus

1 º L e t t h e m i n i a r m d r o p

2º Make sure the mini
arm's plastic part is
fitted into the steel
part.

3º Fit the stainless steel
arm in the mini arm

4º Fixate the screw
inside the mini arm
u s i n g a A l l e n n . 8
wrench

5º Put the arm back into
its normal position.

Содержание CATRAX Plus

Страница 1: ...11 Product Manual plus...

Страница 2: ...22...

Страница 3: ...anslated into any language or computer language in any electronic magnetic optical chemical manual way or otherwise without the express written permission from Digicon S A Code 069 31 252 Version 08 E...

Страница 4: ...6 4 1 3 Pictogram s connection 6 4 2 Configuration of control board Switch Ds1 6 4 3 Outputs 6 4 3 1 Return signals 6 4 3 2 Electromagnets 6 4 3 3 Sound alarm 6 4 4 Examples of some configurations 6...

Страница 5: ...something Digicon considers important CAUTION Indicates a moment of extreme caution when handling the equipment product ATTENTION Indicates a moment when your observation skills should be extremely pr...

Страница 6: ...ion in this manual and cannot be held responsible for errors it may contain and problems due to its use The information contained in this manual is exclusive property of Digicon and is protected by co...

Страница 7: ...Access to the mounting rack is done through a key with secret whose removal and insertion are extremely easy A plastic cover and a stainless steel sheet compose the upper panel The cover made of injec...

Страница 8: ...quipment will allow the turning of the arm of CATRAX Plus After half of the turning is complete 60 degrees a 400 milliseconds returning signal will be sent informing the passage direction After the si...

Страница 9: ...can compose CATRAX Plus plus Left to right direction Right to left direction ATENTION To avoid losses the screws and the wrenches used for assembling the are attached to the box containing the CATRAX...

Страница 10: ...TRAX Plus is assembled 6 If the floor is in conditions to receive anchor bolts minimum of 4 cm of FCK15 M P A concrete or equivalent 5 3 Column fixation To fixate the column to the floor observe the f...

Страница 11: ...ble the arms and plastic covers The image below shows the specific parts of arms and upper frontal CATRAX Plus s cover with assembling instructions plus TIP As an optional item Digicon can provide a s...

Страница 12: ...cover Rear cover Colector box s socket kit plus plus Then assemble the upper panel s rear cover The image below shows the parts corresponding to each phase Fiat washer M3 lock washer M3 and hex nut M...

Страница 13: ...ey that accompanies the equipment in three ways 5 5 1 Rear cover 1 Open the lock with the smaller key clockwise 2 Carefully raise the cover 3 Brag the cover backwards As shown below 5 5 2 Frontal cove...

Страница 14: ...14 plus 5 5 3 Column cover 1 Open the lock with the smaller key clockwise 2 Pull the cover forward 3 The cover will be loose As shown below...

Страница 15: ...he description of each of these items 6 1 Collecting box kit The collecting box kit has a device for collecting retaining and gathering cards or badges It is ideal for places with eventual visitors or...

Страница 16: ...ssage blocking red X plus INFORMATION The box for cards is part of the kit and is positioned under the collecting kit The badge reader is not part of the kit Card reader not included in the kit To the...

Страница 17: ...AX Among the main line advantages of this optional item is its adaptation capability to the voltage variations often found in installation sites the input voltage can vary between 100 and 240 Vca The...

Страница 18: ...partial totalizer To reset the partial totalizer it is necessary to access the partial visualization mode and then press the function key for about 3 seconds or until all the digits are zero Configura...

Страница 19: ...HAB2 enables turn through dry contact from left to right 6 GND 7 12Vcc available to auxiliary maximum 500 mA 8 CLOCK1 input for reader from left to right 9 DATA1 input for reader from left to right 10...

Страница 20: ...tromagnet 2 Electromagnet 2 CN6 OPTICAL SENSORS Sensor 1 signal LED 1 anode Sensor 2 signal GND LED 2 anode plus INFORMATION The cables of the optical sensors CN6 and the electromagnets CN5 are provid...

Страница 21: ...110 to 220 Vca cc To enable passage through relay contact or pushbutton make the connection as shown below Enabling passage through tension pulse is shown in the image below It is necessary to observe...

Страница 22: ...y or pushbutton contact normally open and without input voltage enabling passage in face of these signals or NC inputs relay or pushbutton contact usually closed and with input voltage enabling passag...

Страница 23: ...he outputs according to the image below plus 01 02 03 04 05 06 07 08 Cleared in both directions OFF OFF Blocked from left to right ON OFF Blocked form right to left OFF ON Blocked in both directions O...

Страница 24: ...N ON 1 2 3 4 5 6 7 8 Configuration ON ON ON ON ON ON 6 4 3 2 Electromagnets Electromagnets are activated for blocking the turnstile Opposite to the traditional solenoids electromagnets do not cause ab...

Страница 25: ...vice is deactivated dropping the arm that prevents turn clearing the entrance of any barrier This device can be connected in series allowing the clearance of all turnstiles at once from one single poi...

Страница 26: ...ow The wrench used for assembling must be an Allen n 8 and the screw must be tightened to the maximum to ensure good fixation All three arms must be attached to the same central upper point plus 1 Let...

Страница 27: ...e If the mechanism presents any defect request maintenance to a Digicon technician or a qualified company Each inspection should carry out the following operational sequence for each of the three arm...

Страница 28: ...han 0 8Vcc non obstructed sensors With the pointers at the same position force the equipment s arms to both directions in one of the sides the voltage should be higher than 4 5Vcc Repeat the same oper...

Страница 29: ...es To check for the need of corrective actions you must check the lock s correct position check the wear of the lock s fitting in the sprocket Corrective actions 1 if the lock s position is incorrect...

Страница 30: ...net turnstile cannot be locked The cable is broken or the distance between the electromagnet and the locking device is maladjusted Adjust the electromagnet or forward the equipment to the Technical As...

Страница 31: ...710 27 952 210 8 267 1000 39 409 480 18 897 390 15 534 860 33 937 8 Technical characteristics 8 1 Dimensions plus INFORMATION The measures presented in this manual are in millimeters and inches 160 6...

Страница 32: ...s power 5 Vcc and 0 5 A Power supply optional Input 100 Vca and 240 Vca Output 12 Vca 5 3 A Dimensions 35 x 51 x 105 mm Distance between holes 43 x 98 cm Diameter of holes 3 5 mm Board with display Po...

Страница 33: ...But be careful never scrape the surface of stainless steel with thick blades spatulas or abrasives Rust spots With a cotton swab dipped in water and nitric acid at 10 make topical applications keeping...

Страница 34: ...If this is not enough to soften burned foods or charred deposits use more aggressive products such as caustic soda removers used in household cleaning TIP Even in the case of stubborn dirt try cleani...

Страница 35: ...r technical assistance 3 Warranty shall be granted to the buyer only in the face of the bill of sale original or copy 4 Warranty does not apply in the following cases or conditions a defects and damag...

Страница 36: ...36 36...

Страница 37: ...94045 420 Vendas 0xx51 3489 8700 3489 8745 Assist ncia t cnica 0xx51 3489 8903 E mail vendas acesso digicon com br Filial SP Desenvolvimento e Vendas Assist ncia T cnica Rua S o Paulo 82 Alphaville B...

Отзывы:

Похожие инструкции для CATRAX Plus