Warranty and technical assistance

Digicon is responsible for the project, skilled labor, and quality of the materials used in the
manufacturing of our products, ensuring that the equipment and all parts are free of
manufacturing defects or problems. Digicon commits itself to replace or repair, as we choose,
any part or equipment presenting manufacturing defects without any costs to the buyer, in our
factory in Gravataí or our branch office in São Paulo, in the conditions set below:

1.

The buyer is responsible for the costs of shipping (return service) of the product to the factory

in Gravataí or the branch office in São Paulo.

2.

The warranty period is counted from the date of emission of the bill of sale and encompasses:

a) 12 (twelve) months for equipment, accessories, parts, and pieces, including the legal

warranty period of 90 (ninety) days.

Legal warranty

The customer has the period of 90 (ninety) days, from the date of emission of the bill of sale, to

complain about apparent defects (easily observable in the product), such as the items that
constitute the product's exterior and any other area accessible to the user, just like appearance
parts and general accessories.

b) 90 (ninety) days for repairs or technical assistance

3.

Warranty shall be granted to the buyer only in the face of the bill of sale (original or copy).

4.

Warranty does not apply in the following cases or conditions:

a) defects and damages caused by accidents, negligence, or reasons of force majeure
b) defects and damages caused by inappropriate storage or lack of prolonged use
c) defects and damages caused by improper use of the equipment
d) defects and damages caused by improper operation or installation of the equipment
e) vandalism
f) natural impacts (lightning, flooding, etc.)
g)defects and damages caused by abnormal temperature conditions, voltage/frequency, or

humidity out of the levels specified in the installation and operation manual, once proven

h) reconditioning, chrome plating, nickel plating, and painting

5.

Warranty shall be automatically canceled for equipment that:

a) suffers modifications, adaptations, or any alterations performed by the client or by third

parties without Digicon's written consent

b) goes through maintenance or repairs by people not authorized by Digicon
c) suffers alteration of serial number or violation of the identification label
d) is not paid for in the conditions, amounts, and deadlines described in the bill of sale

6.

Digicon is not responsible for eventual losses suffered by the down time of the equipment

7.

The repair of a warranted product will be performed inside the Digicon facilities.

31

Содержание catrax fit

Страница 1: ...Product manual...

Страница 2: ......

Страница 3: ...d stored in a retrieval system translated into any language or computer language in any electronic magnetic optical chemical manual way or otherwise without the express written permission from Digicon...

Страница 4: ...r kit 14 6 3 Power supply 16 6 4 Control board 17 6 4 1 Inputs 20 6 4 1 1 Connection scheme 21 6 4 1 2 Pictogram 21 6 4 1 3 Pictogram s connections 21 6 4 2 Configuration of control board Switch Ds1 2...

Страница 5: ...tes something Digicon considers important CAUTION Indicates a moment of extreme caution when handling the equipment product ATTENTION Indicates a moment when your observation skills should be extremel...

Страница 6: ...e information in this manual and cannot be held responsible for errors it may contain and problems due to its use The information contained in this manual is exclusive property of Digicon and is prote...

Страница 7: ...nal holes Access to the support is done through a key with secret whose removal and insertion are extremely easy A plastic cover and a stainless steel sheet compose the upper panel The cover made of i...

Страница 8: ...inputs depending on the passage direction If this signal is recognized the equipment will allow the turning of the arm of C Fit After half of the turning is complete 60 degrees a 400 milliseconds atra...

Страница 9: ...uring inspection accompanies all Digicon packages See below the parts that can compose C Fit atrax ATTENTION To avoid losses the screws and the wrenches used for assembling the C Fit are attached to t...

Страница 10: ...panel and plug s locks for the cables passage if there will be enough space for the arms after C Fit is assembled atrax If the floor is in conditions to receive anchor bolts minimum of 4 cm of FCK15 M...

Страница 11: ...t 25mm of the bolt out of the hole 4 Position the column and fasten it to the floor with the four screws that accompany the bolts Use a flex head socket wrench with or an articulated socket wrench 5 4...

Страница 12: ...interior of the equipment can be done with the key that accompanies the equipment 5 5 1 Cover 1 Open the lock with the smaller key clockwise 2 Unscrew the two screws in the turnstile s front 3 Pull t...

Страница 13: ...y however Digicon offers a range of optional items that allow enhancing and matching the equipment s performance to the client s needs See the description of each of these items 6 1 Pictogram kit The...

Страница 14: ...pulses like the other counters available in the market The Digicon electronic counter works through a key button that allows access to all its functions Optionally there is the possibility of the ins...

Страница 15: ...n of partial counter Visualization of total counter Resetting the partial totalizer To reset the partial totalizer it is necessary to access the partial visualization mode and then press the function...

Страница 16: ...and environmental conditions which ensures the adequate power supply to the equipment s performance Besides the input and output voltages indicated in the image below the supply has a short circuit an...

Страница 17: ...ket The controller have mechanical features and layout perfectly suited for the C Fit s needs and it is one of the best options for the equipment s atrax operation The following image shows the contro...

Страница 18: ...ht 10 CLOCK2 input for reader from right to left 11 DATA2 input for reader from right to left 12 GND CN2 OUTPUTS 1 NO or NC Contact HAB1 return 2 Contact C HAB1 return 3 NO or NC Contact HAB2 return 4...

Страница 19: ...signal 3 GND 4 GND CN5 ELECTROMAGNETS electromagnet 1 electromagnet 1 electromagnet 2 electromagnet 2 CN6 OPTICAL SENSORS Sensor 1 signal LED 1 anode Sensor 2 signal GND LED 2 anode INFORMATION The c...

Страница 20: ...220 V c c d ac d To enable passage through relay contact or pushbutton make the connection as shown below Enabling passage through tension pulse is shown in the image below It is necessary to observe...

Страница 21: ...s maximum 500 mA at the moment of activation the GND is sent through a corresponding output 6 4 1 3 Pictogram connections 21 INPUTS INPUTS OUTPUTS RALAY ACCESS CONTROL BOARD OUTPUTS DIGICON CONTROL BO...

Страница 22: ...ning there is no mechanical wear and two opto isolated inputs for liberating Catrax Fit if necessary 6 4 3 Outputs The C Fit board presents outputs for return signals electromagnets pictograms atrax c...

Страница 23: ...brasion between the coil and the locking device avoiding malfunctions Moreover the activation is done through a transistor and not a relay avoiding the electromagnet to be blown due to the contact wie...

Страница 24: ...tion always cleared and when the HAB2 clockwise clearance signal is received clear passage for counter undetermined period 3 Configuration of controller to clear the turning while the relay has the co...

Страница 25: ...m raised during normal operation In case of power outage when the installation has no no break or through a command sent via system or the activation of an emergency button in the control room the ele...

Страница 26: ...0 8Vcc non obstructed sensors With the pointers at the same position force the equipment s arms to both directions in one of the sides the voltage should be higher than 4 5V c d Repeat the same operat...

Страница 27: ...es To check for the need of corrective actions you must check the lock s correct position check the wear of the lock s fitting to the sprocket Corrective actions 1 if the lock s position is incorrect...

Страница 28: ...net turnstile cannot be locked The cable is broken or the distance between the electromagnet and the locking device is maladjusted Adjust the electromagnet or forward the equipment to the Technical As...

Страница 29: ...8 Technical characteristics 8 1 Dimensions 29 730 28 740 93 3 661 860 33 585 1000 39 370 685 26 968 210 8 267...

Страница 30: ...Electromagnets power 12 Vcc and 12 A Sensors power 5 Vcc and 0 5 A Power supply optional Input 100 Vac and 240 Vca Output 12 Vac 5 3 A Dimensions 35 x 51 x 105 mm Distance between holes 43 x 98 cm Dia...

Страница 31: ...technical assistance 3 Warranty shall be granted to the buyer only in the face of the bill of sale original or copy 4 Warranty does not apply in the following cases or conditions a defects and damage...

Страница 32: ......

Страница 33: ......

Страница 34: ...el 640 Distrito Industrial Gravata RS CEP 94045 420 Vendas 0xx51 3489 8700 3489 8745 Assist ncia t cnica 0xx51 3489 8903 E mail vendas acesso digicon com br Branch office SP Rua S o Paulo 82 Alphavill...

Отзывы: