digico D5 Live Скачать руководство пользователя страница 3

Page 3 

Copyright © 2002  Digico (UK) Ltd 

All rights reserved. 

No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any 
form by any means without the written permission of Digico UK Ltd.  Information in this manual is subject to change without notice, and 
does not represent a commitment on the part of the vendor.  Digico UK Ltd shall not be liable for any loss or damage whatsoever arising 
from the use of information or any error contained in this manual. 
All repair and service of the D5 product should be undertaken by Digico UK Ltd or its authorised agents.  Digico UK Ltd cannot accept any 
liability whatsoever for any loss or damage caused by service, maintenance, or repair by unauthorised personnel. 

Digico UK Ltd 
The School House 
4 Dorking Road 
Epsom 
Surrey 
KT18 7LX 
England 
Telephone: 

+44 (0)1372 845600 

Fax: 

+44 (0)1372 845656 

Email: 

[email protected] 

WWW: 

http://www.digiconsoles.com 

All trademarks are acknowledged as the property of their respective owners 

Manual Issue: Issue B, Jan  2003 

D5 Connection and Installation Manual   Contents 

Quick Start Guide  ............................................................................ 4 

Introduction  ..................................................................................... 6 

Worksurface Notes .......................................................................... 6 

Rack Notes ....................................................................................... 7 

Synchronisation Connections ........................................................ 9 

Connector Tables  .......................................................................... 10 

Optical connections  ...................................................................... 11 

Multiple Rack Optical setup  ......................................................... 11 

External Displays  .......................................................................... 13 

Miscelaneous Notes ...................................................................... 15 

Hardware confirgurations ............................................................. 16 

Index  ............................................................................................... 17 

Diagrams 

Electrical Safety Warning  .............................................................

Unlike most large conventional analogue consoles, the D5 worksurface 
contains its own mains power supply, and a variety of internal supply units 
and converters.  These are fully insulated and covered to meet the relevant 
electrical safety standards, but technicians working within the console should 
be aware of the presence of mains voltage
Note also the rack PSU if operated removed from the chassis has heatsinks 
exposed that are live to mains voltage
Also, D5 contains a number of back-lit flat screen displays. The illumination 
system of these displays uses line voltages of up to several KV, generated by 
high frequency DC - DC converters located close to the displays. Touching or 
tampering with these circuits will put a technician at risk of very damaging RF 
burns to the skin and/or high voltage electric shock

Содержание D5 Live

Страница 1: ...INTERCONNECTION SYSTEM SETUP INSTALLATION MANUAL INCLUDING QUICK START GUIDE ISSUEB DIGITAL CONSOLE...

Страница 2: ...Setup Installation Manual Page2...

Страница 3: ...of their respective owners Manual Issue Issue B Jan 2003 D5 Connection and Installation Manual Contents Quick Start Guide 4 Introduction 6 Worksurface Notes 6 Rack Notes 7 Synchronisation Connections...

Страница 4: ...ixer will start up in exactly the same configuration as last switched off GETTING A BASIC AUDIO SIGNAL SETUP As default all inputs are routed to masters 6 Connect a CD to input channels 9 10 on the lo...

Страница 5: ...Page5...

Страница 6: ...her digital consoles The Worksurface The D5 Worksurface is in many ways very similar to any large analogue mixing console One key differ ence however is that no analogue signals are connected directly...

Страница 7: ...s subject upon request Rack Control Panel Connections The Rack Unit control panel provides connectors as follows MADI A IN OUT 2 x BNC MADI B IN OUT 2 x BNC OPTOCORE A IN OUT HMA Optical stage rack on...

Страница 8: ...nce video cable such as RG59 U cable should be used If in doubt about the suitability of a particular cable type a sample of the correct length can be tested with the system prior to installation to p...

Страница 9: ...rs for Word Clock and Video Sync either of which can be used as the master sync source Although the Video Sync input carries only a frame boundary signal the console generates a full digital word cloc...

Страница 10: ...e on only 1 supply Supply units can be switched off removed and replaced whilst the other is use hot swappable I O Rack Control Panel Function Connector Comments MADI I O BNCsocket 2 Pairs of I O to C...

Страница 11: ...even in the event of a cable being destroyed This option is to be implemented in 1st quarter 2003 The final rack in the daisy chain can be connected back to the mixer with an extra optionally supplie...

Страница 12: ...in it can also cause the light pipe to break It should be noted that the optical cable is not repairable on site It is best considered that it is not repair able at all and treated with due care In g...

Страница 13: ...ern SVGA monitor to the required output socket and place this in a convenient position usually above the mixer The overview output has adjustable resolution This is shipped set to 1024 x 760 as this s...

Страница 14: ...ings shows the 5 screens Light the top screen by clicking on it 1 time This the over screen With the slide bar below setting the correct resolution for your screen Use 256 colours or High colour only...

Страница 15: ...6Kb GSM mobile phone type connections are not fast enough the absolute mini mum required for meaningful use is approximately 20Kb In addition a separate speech telephone should be provided to allow an...

Страница 16: ...core System 1st Stage Rack 56 Mic Inputs 8 Analogue Line Outputs Optical MADI Interface and optical cable drum with 100m 2nd Stage Rack 40 Mic Inputs 8 Analogue Line Outputs Optical MADI Interface wit...

Страница 17: ...monitors 12 E External display 13 H Headphones 6 I I O Rack 7 L Lighting 6 M MADI Cables 7 Modem 15 O Optical cables 12 Optical cables 12 Optocore System 11 Overview screen 14 P Paint Finishes 15 R Ra...

Страница 18: ...Setup Installation Manual Page18...

Отзывы: