Rear Panel 

 

 

 

 

  

Network

 

– Fast Ethernet, PoE compliant Network port for 

connection to the mixing system.  

 The A-CONTROL6 provides a locking Neutrik EtherCon socket 

to protect the connection. Use cables fitted with locking EtherCon 
for touring or rental applications. 

 The maximum cable length is 100m. Use STP (shielded twisted 

pair)  CAT5  or  higher  cables.  Those  with  both  foil  and  braided 
screens provide shielding from interference and are generally more 
rugged.  Stranded  core  cables  are  less  prone  to  damage  when 
kinked  or  repeatedly  coiled.  Refer  to 

www.digico.biz

  for  a  list  of 

CAT5 cables available to order. 

   

Ext  DC  In

 

–  External  PSU  input.  Alternatively,  the  A-

CONTROL6 can be powered via the Network port when connected 
to a PoE switch.  

A plastic P-clip cable clamp is provided to secure the DC cable.  

 Only use the power supply provided in the box. 

  

Reset Network Settings

 - A recessed switch lets you 

reset  the  network  settings  to  factory  default.  To  reset,  insert  a 
pointed object to press the switch whilst applying power to the unit, 
then release. 

 

Содержание 4RE4 A-CONTROL6

Страница 1: ...Remote Controller Getting Started Guide A CONTROL6 Before starting please check www digico biz for the latest firmware and documentation AP11451 Issue 1...

Страница 2: ...under the terms of this warranty may be fulfilled with functionally equivalent service exchange units This warranty is not transferable This warranty will be the purchaser s sole and exclusive remedy...

Страница 3: ...o UK Ltd product and the software within it you agree to be bound by the terms of the relevant End User Licence Agreement EULA a copy of which can be found at http www digico biz docs about legal shtm...

Страница 4: ...UK Ltd website DiGiCo UK Ltd do not accept liability for damage caused by maintenance repair or modification by unauthorised personnel Your product This product complies with the European Electromagn...

Страница 5: ...Introduction 6 2 Mounting the Remote Controller 7 2 1 Plinth mount 7 3 Front Panel 8 4 Rear Panel 10 5 Connect and power up 11 5 1 Set up the unit Name and IP Address 11 5 2 4REA4 connection 12 5 3 Et...

Страница 6: ...frastructure It can be powered by an external 12V PSU or over Ethernet PoE The A CONTROL6 controls and functions are programmed using the 4REA4 Controller software for PC Mac and can suit a number of...

Страница 7: ...sed free standing or mounted on a standard microphone with the DiGiCo Mic Stand Adaptor 2 1 Plinth mount Use the holes indicated below for 6B screws when mounting in a plinth podium or furniture Ensur...

Страница 8: ...of a vertical Rotary Strip Available functions include Send On Off Solo Mute Snapshot Recall Talkback Assign LCD Displays 6x colour displays providing information on the channels and on the function...

Страница 9: ...utton Alt View Assignable key Can be configured to show alternative information on the LCD displays Other available functions include Send On Off Solo Mute Snapshot Recall Talkback Assign Buttons Laye...

Страница 10: ...elding from interference and are generally more rugged Stranded core cables are less prone to damage when kinked or repeatedly coiled Refer to www digico biz for a list of CAT5 cables available to ord...

Страница 11: ...255 255 0 Gateway 192 168 1 254 There are two ways of editing these settings Browser access Connect a PC or Mac computer to the Network port of the A CONTROL6 Set your computer to a compatible static...

Страница 12: ...a few seconds the A CONTROL6 will display the assignments and functions if any have been set for the unit If the firmware in a connected A Control Remote Controller is not the same version as that in...

Страница 13: ...can assign each key or rotary individually or use the Quick Setup function to get started quickly The functions and assignments of the A CONTROL6 are stored in the 4REA4 They are not stored locally o...

Страница 14: ...A Control6 Getting Started Guide 14 AP11451 Issue 1 6 Dimensions...

Страница 15: ...00MBps Ext DC In 12V 2 5A PoE 802 3af 15 4W at source Max power consumption 5W Operating Temperature Range 0 deg C to 35 deg C 32 deg F to 95 deg F Dimensions and Weights Width x Depth x Height x Weig...

Отзывы: