AT commands
Special commands
XBee/XBee-PRO DigiMesh 2.4 RF Module User Guide
72
Special commands
The following commands are special commands.
AC (Apply Changes)
Immediately applies new settings without exiting Command mode.
Parameter range
N/A
Default
N/A
FR (Software Reset)
Resets the device. The device responds immediately with an
OK
and performs a reset 100 ms later.
If you issue
FR
while the device is in Command Mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A
RE (Restore Defaults)
Restore device parameters to factory defaults.
Parameter range
N/A
Default
N/A
WR (Write)
Writes parameter values to non-volatile memory so that parameter modifications persist through
subsequent resets.
Note
Once you issue a
WR
command, do not send any additional characters to the device until after
you receive the
OK
response.
Parameter range
N/A
Default
N/A