![Digi XBee DigiMesh 2.4 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/digi/xbee-digimesh-2-4/xbee-digimesh-2-4_user-manual_2496252082.webp)
AT commands
Diagnostic - addressing commands
XBee/XBee-PRO DigiMesh 2.4 RF Module User Guide
82
Parameter range
0 - 0xFFFF
Default
0x11 (Transparent data cluster ID)
DE command
Sets or displays the application layer destination ID value. The value is used as the destination
endpoint for all data transmissions. The default value (0xE8) is the Digi data endpoint.
Parameter range
0 - 0xFF
Default
0xE8
SE (Source Endpoint)
Sets or displays the application layer source endpoint value. The value is used as the source endpoint
for all data transmissions. The default value (0xE8) is the Digi data endpoint.
Parameter range
0 - 0xFF
Default
0xE8
Diagnostic - addressing commands
The following AT command is a Diagnostic - addressing command.
N? (Network Discovery Timeout)
The maximum response time, in milliseconds, for
ND
(Network Discovery) responses and
DN
(Discover
Node) responses. The timeout is based on the
NT
(Network Discovery Back-off Time) and the network
propagation time.
Parameter range
[read-only]
Default
0x3D6A
Addressing discovery/configuration commands
AG (Aggregator Support)
The
AG
command sends a broadcast through the network that has the following effects on nodes that
receive the broadcast:
Содержание XBee DigiMesh 2.4
Страница 1: ...XBee XBee PRO DigiMesh 2 4 Radio Frequency RF Module User Guide...
Страница 63: ...Sleep modes Synchronization messages XBee XBee PRO DigiMesh 2 4 RF Module User Guide 63...
Страница 105: ...Operate in API mode API mode overview 106 API frames 110 XBee XBee PRO DigiMesh 2 4 RF Module User Guide 105...
Страница 112: ...Operate in API mode API frames XBee XBee PRO DigiMesh 2 4 RF Module User Guide 112...