AT commands
MicroPython commands
Digi XBee® 3 802.15.4 RF Module User Guide
175
Default
0x130000
CK (Configuration CRC)
Reads the cyclic redundancy check (CRC) of the current AT command configuration settings to
determine if the configuration has changed.
After a firmware update this command may return a different value.
Parameter range
0 - 0xFFFF [read-only]
Default
N/A
FR (Software Reset)
Resets the device. The device responds immediately with an
OK
and performs a reset 100 ms later.
If you issue
FR
while the device is in Command mode, the reset effectively exits Command mode.
Parameter range
N/A
Default
N/A
MicroPython commands
The following commands relate to using MicroPython on the XBee 3 802.15.4 RF Module.
PS (Python Startup)
Sets whether or not the XBee 3 802.15.4 RF Module runs the stored Python code at startup.
Range
0 - 1
Parameter
Description
0
Do not run stored Python code at startup.
1
Run stored Python code at startup.
Default
0
PY (MicroPython Command)
Interact with the XBee 3 802.15.4 RF Module using MicroPython.
PY
is a command with sub-
commands. These sub-commands are arguments to
PY
.