background image

Digi TransPort® WR21 Installation Guide

Page 9

3  Installation 

Mounting Tips 

The Digi TransPort WR21 should be positioned on a flat, level surface or via a wall-mount, rackmount, or DIN 

rail mounting brackets (see the Accessories section on page 18 for all options). The unit is designed for indoor 

use and should be mounted in a location with adequate ventilation. Also, do not expose the unit to extremes 

of heat or cold, strong magnetic fields, or liquids.

Step 1) (SIM card models only) - Install the SIM card(s):

 SIM card(s) should be inserted into SIM Sockets 

as illustrated in the above Front View image. For SIM 1, the contacts should be face down. For SIM 2, the 

contacts should be face up. In both cases, the end of the SIM card with the chamfered corner should be 

inserted first.

The Digi TransPort WR21 also allows for dual network installations where one wireless service can be used 

as a back-up in the event that the primary service fails. These installations cannot be used to access two 

networks simultaneously. By default, SIM 1 is used for access to the primary network and SIM 2 is used for 

the back-up network. 

 

Содержание TransPort WR21

Страница 1: ...T r a n s P o r t W R 2 1 Wireless Routers Installation Guide January 30 2012 ...

Страница 2: ... If the power supply shows signs of damage or malfunction stop using it immediately turn off the power and disconnect the power supply before contacting your supplier for a repair or replacement 3 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Use only the accessories attachments and power supplies pr...

Страница 3: ...al danger contact the physician or the manufacturer of the device to verify that the equipment is properly shielded Pacemaker patients are advised to keep the wireless router away from the pacemaker while it is on Wireless routers must NOT be operated on aircraft The operation of wireless appliances in an aircraft is forbidden to prevent interference with communications systems Failure to observe ...

Страница 4: ...stallation 9 4 Configuration 11 4 1 Network Settings 11 4 2 Web Interface 11 4 3 Command Line Interface CLI 14 5 Troubleshooting 16 5 1 Troubleshooting Resources 16 5 2 Unable to open the Web Interface 16 5 3 Unable to log in to the Web Interface 16 6 Specifications 17 7 Accessories 18 Appendix A SERIAL 0 Port Pin out Diagram 19 Appendix B Software Options 20 ...

Страница 5: ...that may have occurred during shipping and report it to the carrier Depending on model and configuration the package will also contain additional cables antennas as appropriate TransPort WR21 Installation Guide Ethernet Cable Power Supply some models may include a DC Power Cord or have no Power Supply Power Supply Adapters Non US models only Cellular Antenna s ...

Страница 6: ...r router offering the flexibility to scale from basic connectivity applications to enterprise class routing and security solutions With its high performance architecture Digi TransPort WR21 is designed for Wide Area Network connectivity including 2 5G 3G 4G networks Digi TransPort WR21 is available with a range of Ethernet Serial RS232 RS422 485 and Power connector options Digi TransPort WR21 also...

Страница 7: ...dicator SIGNAL 0 LEDs illuminated 113 dBm effectively no signal 1 LED illuminated 112 dBm and 87 dBm weak 2 LEDs illuminated 86 dBm and 71 dBm medium 3 LEDs illuminated 70 dBm and 51 dBm strong 6 USB Host Connector The USB host connector may be used to connect compatible USB 2 0 client devices such as memory sticks and serial adapters The total current available to power USB devices is 0 5A 7 Rese...

Страница 8: ...ronous RS232 RS485 optional serial port with optional RS422 485 support which may be which may be used to connect the unit to a compatible serial device This is a DCE serial port and allows CLI access to the device by default the baud rate is 115200 A pinout diagram is available in Appendix A SERIAL 0 Port Pin out Diagram on page 19 5 Power Cord Input This socket is used to connect the unit to a p...

Страница 9: ...ep 1 SIM card models only Install the SIM card s SIM card s should be inserted into SIM Sockets as illustrated in the above Front View image For SIM 1 the contacts should be face down For SIM 2 the contacts should be face up In both cases the end of the SIM card with the chamfered corner should be inserted first The Digi TransPort WR21 also allows for dual network installations where one wireless ...

Страница 10: ...e not included to the SERIAL 0 port on the unit and other end to the serial port on a third party serial terminal device If you wish to connect the unit to a PC it is recommended that you purchase Digi s serial cable P N 76000858 Step 5 Connect the Power Supply Barrel Plug Type Variants Connect the barrel plug end of the power supply to the power connector on the unit and plug the other end into a...

Страница 11: ...manually configure your PC to be on the 192 168 1 x network for example with an IP address of 192 168 1 2 and subnet mask of 255 255 255 0 Care should be taken to ensure that the unit does not conflict with other devices that may already be on the network 4 2 Web Interface Step 1 Connect to the Web Interface Open a Web browser e g Firefox IE Chrome on your PC and navigate to http 192 168 1 1 If su...

Страница 12: ...ed on the network before it can make a connection Note If your unit uses a Gobi module indicated by a model number of WR21 U5xx xxx xx and you did not select the appropriate CDMA carrier via the Quick Start Wizard you must run the GOBI Module Carrier Wizard before provisioning can be successfully completed To provision the CDMA mobile device navigate to the CDMA Provisioning section by clicking on...

Страница 13: ...ttings are required in the Web Interface simply press Start in the Automatic section and leave the fields blank Sprint has two types of plans Vision for standard Internet connections and DataLink for private IP plans 1 Sprint Vision uses Automatic provisioning There are three fields of information that may need to be populated in the Automatic screen Check with Sprint for correct values if require...

Страница 14: ...top Bits 1 Parity No Parity Flow Control None Step 2 Ensure the connection is active by entering the command AT If the device is functioning properly it will return the response OK Step 3 Ensure the COM port is setup correctly by entering the command ATI5 4 3 3 Network Settings To configure the unit with an IP address as part of an existing network use the commands below Note The DHCP server will ...

Страница 15: ...To retain the DHCP server but on a different subnet the following parameters will need to be configured Command Description DHCP 0 IPMIN x x x x Minimum IP address to assign the start of the DHCP pool DHCP 0 IPRANGE The number of IP addresses in the DHCP pool DHCP 0 GATEWAY x x x x The IP gateway address the DHCP clients should use normally this router s LAN IP address DHCP 0 MASK x x x x The subn...

Страница 16: ...he status indicator is illuminated check that the PC can communicate with the unit To do this open the Command Prompt window on your PC and enter the command ping 192 168 1 1 If you do not get a response then the problem could be one of the following The IP address of the unit has been changed from its default of 192 168 1 1 Use the Digi TransPort Connection Wizard which can be downloaded from the...

Страница 17: ...0 MHz 3 1 Mbps down 1 8 Mbps up R UIM support Power Requirements Power Input 9 30 VDC Power Supply 100 240 VAC 50 60 Hz with barrel connector optional barrel connector with bare wire leads Power Consumption 6W 12 VDC Environmental Operating Temperature 20 C to 55 C 35 C to 75 C with reduced cellular performance Relative Humidity 20 to 95 non condensing Ethernet Isolation 1 5 kV Serial Port Protect...

Страница 18: ... 10m 76000831 SMA Male to SMA Female 15m 76000832 Antennas Cellular Direct Mount Quad Band 2dBi 76002050 Direct Mount Penta Band 2dBi 76002052 Direct Mount Dual Band 3dBi DC ANT DBDP3 Magnet Mount Penta Band 2 5dBi 76002051 Magnet Mount Dual Band 4 0dBi DC ANT DBHG Glass Mount Quad Band 1 5dBi 76000844 Glass Mount Penta Band 0dBd 76000845 Surface Marine Mount Quad Band 0dBi 2 15dBi 76000864 Surfac...

Страница 19: ... Set Ready 7 In RTS Ready To Send 8 Out CTS Clear To Send 9 Out RI Ring Indicate RS422 RS485 Pin Direction RS422 RS485 Description 1 Out CTS_B Clear To Send B 2 Out RD_A Receive Data A 3 In TD_A Transmit Data A 4 In RTS_B Ready To Send B 5 N A GND Ground 6 Out RD_B Receive Data B 7 In RTS_A Ready To Send A 8 Out CTS_A Clear To Send A 9 In TD_B Transmit B Notes For true RS485 mode 2 wire half duple...

Страница 20: ... SSLv3 FIPS 197 L2TP 5 tunnels included IPSec with IKEv1 IKEv2 ISAKMP DES 3DES and AES up to 256 bit encryption SCEP for X 509 certificates Open VPN client and server PPTP IPSec PPP L2TP VPN Server support Stateful inspection firewall with scripting Content Filtering via 3rd party Routing NAT NATP Bridging NAT NAT Traversal NAPT forwarding PPP PPPoE GRE IP Routing Protocol PPP GRE RIP v1 v2 OSPF S...

Страница 21: ...Standard Version Firewall Advanced Version Firewall Actions block pass Actions block pass pass ifup pass ifupnr debug touser dscp vdscp Options routeto oosed Options onvlan onvrf oneroute routeto oosed Stateful Inspection No Stateful Inspection Yes ...

Страница 22: ... essential requirements and other relevant requirements of the R TTE Directive 1999 5 EC Safety article 3 1a EN60950 1 2006 A11 2009 EMC article 3 1b EN55022 2006 A1 2007 class B EN55024 1998 A1 2001 A2 2003 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 EN301 489 7 v1 3 1 EN 301 489 24 V1 5 1 Spectrum article 3 2 EN301511 v9 0 2 EN301526 v1 1 1 EN301908 1 v3 2 1 Minnesota USA 21st September 20...

Страница 23: ... are recycled using the best available recovery techniques to minimize the impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed with other commercial waste for disposal Check with the terms and conditions of your supplier for disposal information Digi International Ltd WEEE Registration num...

Страница 24: ...or implied including but not limited to the implied warranties of fitness or merchantability for a particular purpose Digi may make improvements and or changes in this manual or in the product s and or the program s described in this manual at any time This product could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes may...

Отзывы: