Install Guide

Model: MIL-02F

2

 

I n t ro d u c t i o n

 

The MIL-02F is an Ethernet, multi-mode fiber transceiver that comes equipped 
with diagnostic LEDs, an AUI male connector, and either an SC- or ST-type fiber 
connector.

 

I n s t a l l a t i o n

 

1. Connect the fiber cables: Attach the fiber cables from the fiber network cabling 

to the fiber connectors on the MIL-02F.

2. Attach the 15-pin AUI connector from the MIL-02F to the DB-15 connector on 

the device you wish to connect to.

3. Tighten the latch screws to secure the unit.

4. Restart the computer. The 

 

PWR

 

 LED illuminates.

 

Note:

 

If the 

 

PWR

 

 LED did not illuminate, reinstall the MIL-02F. If it still does not illuminate, contact 

our technical support department.

 

C o n fi g u r a t i o n

 

The MIL-02F comes with configurable options, which include a 2-position DIP 
switch and a 3-pin jumper. The DIP switch is located on left-side of MIL-02F 
(while facing the device), and the jumper is located inside the device. To open the 
MIL-02F to access the 3-pin jumper:

1. For device's with ST-type connectors,u nscrew the two hex nuts that secure the 

ST-type connectors.

2. Slide the top-half of the enclosure off, over the fiber connectors.

The jumper is located on right-hand side of the device (Figure 1).  

 

D I P   S w i t ch

 

The Link Sentry feature on the MIL-02F is configured through the 2-position DIP 
switch located on the side of the transceiver. Use a mechanical pencil to adjust the 
DIP switches. 

LinkSentry transmits link pulses only if the receive side of the link is seen. This 
allows fault-tolerant transceivers and hubs to detect faulty cables or bad 
equipment. Settings for the DIP switch includes:

 

Table 1: DIP Switch Settings

 

Up (off)

Down (on)

 

Switch 1

LinkSentry disabled (Default)

LinkSentry enabled

Switch 2

SQE disabled (Default)

SQE enabled

Содержание MIL-02F

Страница 1: ... following information Introduction on page 2 Installation on page 2 Configuration on page 2 DIP Switch on page 2 Jumper Settings on page 3 Diagnostic LEDs and Conditions Indicated on page 3 Legal on page 4 FIBER MAU Model MIL 02F ETHERNET FULL DUPLEX 10BASE FL TRANSCEIVER Power Required 12 VDC 200 ma FCC PART 15 CLASS A COMPLIANT CX TX RX PWR LINK TX RX ...

Страница 2: ...n DIP switch and a 3 pin jumper The DIP switch is located on left side of MIL 02F while facing the device and the jumper is located inside the device To open the MIL 02F to access the 3 pin jumper 1 For device s with ST type connectors u nscrew the two hex nuts that secure the ST type connectors 2 Slide the top half of the enclosure off over the fiber connectors The jumper is located on right hand...

Страница 3: ...ed half duplex is selected default Figure 1 Inside the MIL 02F Diagnostic LEDs and Conditions Indicated PWR Power Device is receiving power TX Transmit Packets are being transmitted over the network CX Collision Collisions are occurring on the network RX Receive Packets are being received from the network LINK Link The fiber optic link is good DIP Switch 3 Pin jumper with a jumper block installed ...

Страница 4: ...t serial number and rev Date of purchase Vendor or place of purchase Reach Digi Technical Support at 408 744 2751 Or E mail at sun tech dgii com Address 1299 Orleans Drive Sunnyvale CA 94089 Voice 408 744 2775 Fax 408 744 2793 E mail info dgii com Five Year Limited Warranty Digi International warrants to the original consumer or purchaser that each of its products and all components thereof will b...

Отзывы: