![Digi Connect EZ Mini Скачать руководство пользователя страница 23](http://html.mh-extra.comconnect-ez-mini_user-manual_2496436023.png)
Connect equipment to the Connect EZ serial port
After your device is connected and powered up, you can connect equipment to the device using the
serial ports.
The serial port on the Connect EZ provides console access to connected critical equipment through a
connected Ethernet LAN. Connect your network device to the Connect EZ serial port. For pinout
information, see
Serial connector pinout: Connect EZ Mini
You must use a cable with a DB9 connector to connect to the Connect EZ with a DB9 connector.
Consult the user guide for the device you are connecting to the Connect EZ to determine the
connector type, cable type, and pinout positions for your specific device.
The serial port is enabled by default. The network devices connected to the serial port may be
accessed using RealPort, Digi Remote Manager, the local web user interface, TCP, telnet, or SSH
connections. TCP, telnet and SSH connections to serial ports are disabled by default and must be
enabled by a device-specific configuration.
Serial Status page
The
Serial Status
page contains status information about all of the serial ports available on the
device. To get to this page, choose
Status
>
Connections
>
Serial
.
See
for more information.
Serial connector pinout: Connect EZ Mini
The Connect EZ Mini has a DB9 serial connector. The table below contains the pinout information.
DB-9 pin
EIA-232
EIA-422
EIA-485 Half-duplex
1
DCD
CTS-
Not used
2
RxD
RxD+
Data+
3
TxD
TxD+
Not used (Reserved)
4
DTR
RTS-
Not used
5
GND
GND
GND
6
DSR
RxD-
Data-
7
RTS
RTS+
Not used