5. Confirm the following hardware setup is displayed on the “PC Settings” tab.
Now select the COM port the Digi XBee USB is connected to, and click the “Open
Com Port” button. The message “Radio Found” is displayed to indicate that you
selected the correct COM port. The ZigBee parameters (firmware version, operating
channel, PAN ID) for the Digi XBee USB will be displayed in the “Radio Parameters”
box. Go to
Control Panel > System > Hardware > Device Manager > Ports
on your
PC if you need help in identifying the USB COM port.
6. Any ZigBee devices discovered will be displayed in the “Devices Discovered” window
to the right.
If the utility times out and no ZigBee devices are displayed, you will have to reconfig-
ure the Digi
XBee USB and recompile the sample program once you make sure the
BL4S100/BL4S150 is powered up. The timeout may occur if you are doing develop-
ment simultaneously with more than one ZigBee coordinator. Appendix F explains the
steps to reconfigure the Digi
XBee USB.
•
115200 baud
•
Hardware flow control
•
8 data bits
•
No parity
•
1 stop bit