Troubleshooting

The Smartleer website does not recognize my gateway.

a

Need Help? Call 1-877-693-7849 or visit 

www.digi.com/support

.

ERT 

Power

ERT/Ethernet 

Gateway

b

LED Status Description

Next Step

LED Name

No ERT meter configured

All ERT meters successfully read in the last 

30 minutes

At least one ERT meter has not been read 

in the last 30 minutes

Initial 30 minute setup blink, at least one 

meter has not been read

OFF

ON

Fast Blink

(2 x second period)

Slow Blink

(once every 2 seconds)

Complete Step 3: Online Installation. The “add meter” 

step will guide you through ERT meter configuration.

No further action required

1.  Verify that the ERT/Ethernet gateway is close 

enough to the meter

2.  If blinking persists, call Digi technical support for 

assistance

Wait one minute. If after one minute the LED is not 

solid, follow “Next step” for “Fast Blink” above.

Power 

ERT 

OFF

No power

1.  Verify that the power supply is connected to the 

device and outlet 

2.  If still not operating, call Digi technical support

for assistance

ON

OK

No further action required

Ensure that you have properly connected the Ethernet and power cable (as described in Step 1)
Your router/access point security configuration settings may need to be modified in a home network. Common causes are:

DHCP is not enabled

MAC filtering is enabled (you will need to add the ERT/Ethernet gateway MAC address to the filter table)

You have exceeded the number of DHCP addresses (you will need to increase the allotment)

Though unusual for a home network, it’s not unusual for corporate networks to block outgoing traffic from unknown devices on the network with a firewall.

Make sure outbound TCP ports 3197 and 3199 are open to correct the problem.

Installation of the iPhone/Android application through the Web is failing.

You may manually install the iPhone/Android phone application directly from your phone by:

Using your iPhone, go to the App Store

Using your Android phone, go to the Market

Searching for Digi Smartlee

Once found, install the application. Sign in with the same login and password you created when you opened your Smartlee account online.

c

Are the status LED lights operating correctly?

Ensure that you have properly connected the Ethernet and power cable (as described in Step 1)
ERT/Ethernet gateway LED light behavior: