background image

4.

Attach the cables from the peripheral devices to the SCSI Terminal 
Server.

5.

Connect the power supply and/or power cord to an AC outlet.

6.

Power up the network server and its peripherals. 

7.

Check to see that the SCSI Terminal Server is operating correctly.
Note: See the Troubleshooting section below for common installa-
tion problems.

Rack Mount Installation

For the SCSI Terminal Server 1032, a rack mount kit is included. The 
rack mount brackets may be installed at either the front or rear of the unit. 
To install each bracket, do the following: 

1.

Remove the two screws on the side of the cabinet.

CAUTION:  To prevent electric shock, do not remove the module 

cover. There are no user-serviceable parts inside. Refer 
servicing to qualified personnel only.

2.

Align the holes of the bracket with the vacated holes in the cabinet. 
Use the screws to fasten the bracket to the cabinet.

Rack Mount Considerations

When doing a rack mount installation consider the following:

Cumulative power requirements of the unit and other equipment 
installed in the rack. Do not overload rack supply circuits.

Safety and stability. Always stack the rack from bottom up to ensure 
a stable and safe rack. 

Air flow in the rack. Make sure the unit’s ambient temperature does 
not exceed 95°F (35°C).

Grounding. Earth ground the unit reliably to the rack system. The 
earth ground connection must be maintained when the supply con-
nection is other than a direct connection to the branch circuit.

EIA - 232 Connectors

Many EIA-232 serial devices implement their serial ports with DB-25 
connectors. The SCSI Terminal Server units have serial ports imple-
mented with 8-pin RJ-45 modular jacks, with each signal using EIA-232 
voltage levels. The figures below shows the pinouts of all these connector 
types
Note: The SCSI Terminal Server RJ-45 pin configuration is different 
from the configuration of the RJ-45 connectors used on other Digi prod-
ucts. RJ-45 cables designed for other Digi products must not be used 
with Digi SCSI Terminal Server.

 

EIA-232 DTE and DCE Pinouts

Troubleshooting

If the SCSI Terminal Server does not operate properly, check the list 

below for some common installation problems

The most frequent problem is duplicate SCSI ID numbers. The SCSI 
adapter card is usually set to #7. Make sure the SCSI Terminal 
Server module ID number is not conflicting with that number.

Check the cable to see that it is properly inserted and is completely 
seated. The pins in the SCSI cable are delicate and can be easily bent 
if not inserted carefully. It might be necessary to disconnect the cable 
to inspect for bent pins.

Inspect the power cord to verify it is inserted completely and the 
power is turned on.

Software License Agreement

LICENSE. Digi grants to you only a non-assignable, nonexclusive and non-transferable license to use the 
software contained on this media (herein after “Digi Software”) subject to the terms and conditions of this 
Software License Agreement. Your use will be limited to an object code version of the Digi Software. 
Your use of the Digi Software will be limited to one computer. The license will commence on the day you 
receive the Digi Software and will continue until this license is terminated by its own terms and condi-
tions. You may make one copy of the Digi Software, but only for archival or backup purposes, and if you 
do make that additional copy, you agree to reproduce all copyright and other proprietary rights notices that 
appear on the Digi Software. You are granted only a limited license to use the Digi Software, and Digi 
retains all right, title, interest and ownership in and to the Digi Software, which includes all rights arising 
under the patent, copyright, trade secret or trademark laws of the United States or any foreign jurisdiction.
CONFIDENTIALITY. You understand and agree that the Digi Software contains valuable confidential 
and trade secret information which is the extremely valuable property of Digi. You agree to expend all 
necessary efforts to ensure that the Digi Software is not disclosed or made available to any third party or 
any employee or contractor that doesn’t have a need to know.
REVERSE ENGINEERING. YOU AGREE NOT TO DISASSEMBLE, DECOMPILE OR REVERSE 
ENGINEER THE DIGI SOFTWARE UNDER ANY CIRCUMSTANCES.
WARRANTIES. Digi warrants only that: (a) the media upon which you receive DIGI Software will be free 
of defects in material and workmanship for a period of ninety (90) days from your receipt of the DIGI 
Software; and (b) that if the DIGI Software is supplied to you electronically, and there is an error in trans-
mission, and you inform us of that error within ninety days of your receipt of the DIGI Software, Digi will 
re-transmit the Software to you. You understand and agree that except as stated above, the DIGI Software 
is supplied as is, and Digi expressly disclaims all other warranties, guarantees, or remedies whether 
express, implied or statutory, including, but not limited to, any implied warranty of merchantability or fit-
ness for a particular purpose.
LIABILITY LIMITATIONS. Under no circumstances will Digi or any of its distributors or suppliers be 
liable for loss of data, reprocurement costs, lost revenue or profits or any other special, incidental or conse-
quential damages, even if those damages were foreseeable or you have informed Digi of a potential liabil-
ity. Digi’s total liability to you for damages for any reason shall not exceed the price actually paid to Digi 
by you for the product associated with the Software.
TITLE AND OWNERSHIP. You acknowledge and agree that Digi retains all right, title and interest in and 
to the Software. You agree to indemnify, defend and hold harmless Digi against any loss suffered or 
expenditure made by Digi arising from an assertion of an interest in or title to the Digi Software by you 
and against any breach by you of any copyright, patent rights, or any other rights in the Digi Software.
TERMINATION. You acknowledge and agree that Digi may terminate your license and use of the Digi 
Software without notice if, at any time, you fail to comply with a material term or condition of this Soft-
ware License Agreement. Immediately upon termination of this license, you will return all copies of the 
Digi Software to Digi, together with all documentation, modifications and enhancements thereto, or at 
Digi’s request, destroy all copies of the Digi Software documentation, modifications and enhancements in 
your possession. You understand and agree that in the event of termination, Digi may use computer hard-
ware, software or other methods to render the Digi Software inoperable.
ASSIGNMENT. You may not assign this license without the prior written consent of Digi. Digi may 
assign the Digi Software to any third party at its discretion, but will provide you with written notice in the 
event of such assignment.
CHOICE OF LAW AND VENUE. This Software License Agreement shall be governed and construed in 
accordance with the laws of the State of Minnesota. Any controversy or claim arising out of or related to 
this license and/or your use of the Digi Software shall be venued in Minnesota State District Court, County 
of Hennepin or the United States District Court for the District of Minnesota.
MAINTENANCE AND SUPPORT. Any software maintenance or support services provided to you by 
Digi, are provided at Digi’s discretion, and Digi reserves the right to discontinue and/or commence charg-
ing fees for maintenance or support services at any time. YOU ALSO UNDERSTAND AGREE THAT 
ANY MAINTENANCE OR SUPPORT SERVICES PROVIDED TO YOU BY DIGI ARE PROVIDED 
AS IS, AND DIGI MAKES NO REPRESENTATIONS OR WARRANTIES WITH REGARD TO 
THOSE SERVICES.

Proprietary Rights Notice
Digi, Digi International, the Digi logo, RealPort and PortServer are trademarks or registered trademarks of 
Digi International Inc. in the United States and other countries. All other brand and product names are 
trademarks or registered trademarks of their respective holders.
This manual is copyrighted material proprietary to Digi International Inc. Copying of this manual without 
the express written consent of Digi International Inc. is prohibited and will be treated as copyright 
infringement.
Copyright © 2000 Digi International Inc. All Rights Reserved. http://www.digi.com
Disclaimer

This manual may contain inaccurate or erroneous information. This manual is subject to change at any 
time. This manual, including all information contained herein, is provided “as is” without warranty of 
any kind, either express or implied, including, but not limited to, any implied warrantees of merchant-
ability or fitness for particular purpose. Digi International Inc. makes no representations, warranties, or 
commitments with regard to any data or information contained in this manual. If you rely on data or 
information contained in this manual, such reliance is at your own risk. 

RJ-45 Pin

Signal

DB-25 Pin

DTE Use

DCE Use

1

RTS (out)

4

output

input

2

DSR (in)

6

input

output

3

DCD (in)

8

input

output

4

RxD (in)

3

input

output

5

TxD (out)

2

output

input

6

SG

7

ground

ground

7

DTR (out)

20

output

input

8

CTS (in)

5

input

output

1 3

1

1 4

2 5

M ale D B -25

1 3

1

1 4

2 5

Fem ale D B -25