D3714-US  REV C 

December 17, 2012 

 

 

EZ3400 

Operators Manual 

 

 

 

 

 

 

Ft. Atkinson, Wisconsin  USA 

 

Panningen, The Netherlands 

www.digi-star.com

 

HELLO 

Содержание EZ3400

Страница 1: ...D3714 US REV C December 17 2012 EZ3400 Operators Manual Ft Atkinson Wisconsin USA Panningen The Netherlands www digi star com HELLO...

Страница 2: ...EZ3400 User s Manual D3714 Rev C...

Страница 3: ...oad A Tare Value 13 Mixer Timer 14 Restart Mix Timer 14 To Clear Memory 15 Review Accumulation Values 15 Erase Accumulation Values 15 Print Accumulation Values One Feedline 16 Print Accumulation Value...

Страница 4: ...Receiver 41 Remote Indicators 42 TROUBLESHOOTING 43 LEGAL FOR TRADE CERTIFICATION 45 Legal for Trade Features 45 Sealed to Prevent Un authorized Modifications 46 All rights reserved Reproduction of an...

Страница 5: ...0 V D C 160 mA nominal with four 350 L C SET UP AND CALIBRATION Via front panel GROSS RANGE 999 999 max display LOW BATTERY WARNING Enabled at 10 5V nominal POUND KILOGRAM Selectable DISPLAY STD EZ 6...

Страница 6: ...aners hoses to clean the indicator Charging Battery and Welding Disconnect all cables from the weighing indicator before charging the battery or welding on the machine If cables are left connected the...

Страница 7: ...page 17 3 holds displayed weight when moving machine 4 See pages 14 19 5 turns indicator on Pressing while on will run self test 6 turns indicator off 7 Display Window Displays current actions 8 temp...

Страница 8: ...el numbers for weight value to be displayed and printed 16 clear current command 17 add space in command 18 performs tasks displayed by select 19 displays additional tasks 20 view for additional infor...

Страница 9: ...tor Tare and Net Gross Tare is a temporary zero Net Weight to display total weight Gross Weight Press 1 Press 1 Press and hold for 3 seconds to zero balance indicator 2 Indicator ready to weigh when f...

Страница 10: ...o zero Flashing arrow points to NET 3 Add more weight Example 300 4 Press to show GROSS weight of starting weight of 4000 pounds plus added 300 pounds Flashing arrow points to GROSS 5 Press 300 pounds...

Страница 11: ...ng Using the M RM and CM Options Use these options to weigh truck or wagon one axle at a time 1 Press to send data to printer or PC 1 Add weight on scale Example 500 pounds 2 Repeatedly press until M...

Страница 12: ...ly display 500 pounds added to indicator memory and indicator in gross weight mode 4 Put another weight on scale Example 1000 pounds 5 Repeatedly press until M is displayed 6 Press Indicator adds 1000...

Страница 13: ...RM is displayed 8 Press 9 Total of both weights 1500 pounds displays Indicator switches to GROSS weight mode See page 11 to print weight in memory 1 Repeatedly press until RM displayed 2 Press to sho...

Страница 14: ...seconds to perform weight average 3 Display shows COUNT 2 if number of individual weights to average is two Example weight of 1000 pounds and 500 pounds averaged 4 Displays AVERAG 5 Display shows aver...

Страница 15: ...ration D3714 Rev C EZ3400 User s Manual 11 Printing Average Weight 1 Press while average weight displayed Sample output format shown below 750 1 Counts Average Weight 10JA08 12 01P 2CT 750LB AV Date T...

Страница 16: ...d preset weight 2 Press indicator rounds weight to nearest display count 3 Once preset entered display shows weight loaded or unloaded in one of three display modes shown on page 12 1 Press to clear p...

Страница 17: ...amount remaining to load or unload As ingredients are loaded or unloaded display counts down from entered weight to zero 1 Press twice Displays weight added since preset entered As ingredients are lo...

Страница 18: ...Rev C Mixer Timer Restart Mix Timer 1 Press 2 Enter time press Time runs down alarm sound and timer shows negative for over mixing of set time 3 Press 1 Press twice without entering value starts time...

Страница 19: ...me values were erased Erase Accumulation Values 1 Repeatedly press until CM displayed 2 Press 1 Repeatedly press until ACCUM displayed 2 Press 3 Press displays accumulation of other ingredients 4 Pres...

Страница 20: ...e ingredient accumulation for corn silage 4 Press again to erase all accumulations 5 Press 1 Press to display first ingredient Repeatedly press to display other ingredients 2 Press to change between i...

Страница 21: ...ber Of Ingredients Defines how many ingredients are in the Ingredient Name Table The default is 30 ingredients and 69 pens Pre Alarm Select weight or percentage method enter value to activate early wa...

Страница 22: ...elay Time Changes time indicator waits before automatically advancing to next feedline 1 Enter 442 and press 2 Press to choose tolerance method 3 Press to save 4 To change percentage press until desir...

Страница 23: ...umber of mixer rotations NOTE Feature requires optional sensor kit 1 Enter 421 press 2 Press picks REV option 3 Press to save 4 Press 5 Enter number of rotations 6 Press rotation counter counts down C...

Страница 24: ...ual D3714 Rev C MENUS AND ACCESS NUMBERS Access To Menus 1 Press and hold and 2 Press to choose required menu 3 Press to enter selected menu 4 Press to scroll options 5 Press to change options 6 Press...

Страница 25: ...edient Total of all ingredients must equal 100 in this mode Amount Per Load Allows entry of ingredient amounts required per load Change Entry Method Ingredient Re Name 1 Enter 441 press 2 Repeatedly p...

Страница 26: ...8 Press 9 Press to exit 1 Press to display first ingredient 2 Press to print total accumulations for this ingredient 3 Press again to print accumulations for all ingredients currently used in all rec...

Страница 27: ...scroll available ingredients 6 Press to select ingredient on screen 7 Enter amount of ingredient required see note 8 Press to store amount Repeat steps 5 8 for each ingredient required 9 Press to cha...

Страница 28: ...recipe Repeat steps 1 15 until all recipes programmed 16 Press to exit 1 Press and hold until indicator beeps and displays PROGRM 2 Repeatedly press until recipe number displayed 3 Press to edit this...

Страница 29: ...the current ingredient on the screen 9 Press to switch between ingredients and pens 10 Press to scroll available ingredients or pens 11 Press to select ingredient or pen 12 Enter amount required 13 Pr...

Страница 30: ...llowed by first recipe number 2 Repeatedly press until desired recipe number displayed 3 Press and hold message press zero to erase recipe or net gross to exit scrolls 4 Press to erase recipe 5 Press...

Страница 31: ...ipes NOTE Optional serial port must be installed for printing 1 Press to display first recipe Repeatedly press to display other recipes 2 Press to print recipe 3 Press 1 Press to display first recipe...

Страница 32: ...isplays RESIZE followed by PEN 5 Indicator displays flashing number Change number to amount of animals to feed NOTE If using percent load change number to weight amount for pen 6 Press 7 After RESIZIN...

Страница 33: ...t loaded indicator displays START DELIVERIES 10 Indicator displays pen to unload and how much to unload As pen is unloaded indicator counts down to zero 11 Press to progress to next pen 12 After last...

Страница 34: ...ayed weight from changing while moving Using Dimmer Option 1 Press 2 Press indicator normal 3 If weight added in hold mode press to cancel hold Note This feature is disabled on all legal for trade sys...

Страница 35: ...See page 32 Setup Change setup and calibration numbers See page 37 M Adding weight to weight memory RM Recall weight memory CM Clear weight memory Dimmer High Low backlight control Toggle between high...

Страница 36: ...uage to be displayed DISPLAY RATE 0 rate 102 1 2 3 4 Update display times per second MOTION motion 103 ON OFF If ON motion arrow flashes for unstable weight and will prevent Ingredient or pen advancin...

Страница 37: ...X Select key changes date function key chooses mm dd yy ONE LINE PRINT Il prt 212 ON OFF If ON indicator data will be printed on one line PRINT FORMAT prtfmt 216 AUTO WTONLY DOWNLD DT TM ID TM IDWTTM...

Страница 38: ...g 303 LB KG Display pounds lb or kilograms kg CAPACITY cap 304 40000 Enter MAXIMUM weight measurable on scale MENU 4 PRESET BATCHING COUNTER FEATURES PRE ALARM p mthd p alm 401 WEIGHT PERCNT Select we...

Страница 39: ...SET PNT OUTPUT SETOUT 426 OVER UNDER Select when the 12VDC Alarm Output becomes active SET POINT COUNT SET CTR 427 0 9 Counts activation of Code 423 ENTRY METHOD E MTHD 441 1 2 3 Select batch 1 amount...

Страница 40: ...when advancing ingr While loading mixer NUMBER OF INGREDIENTS NUMING 473 30 0 99 Defines how many ingredients are in the Ingredient Name Table CALIBRATION DEAD WEIGHT CAL CAL 802 Calibration method us...

Страница 41: ...0 User s Manual 37 Change Setup And Calibration Numbers 1 Enter 871 press 2 Indicator shows SETUP briefly then show a 6 digit number Enter new number 3 Press Follow same procedure to change calibratio...

Страница 42: ...403780 SCR 10 X 5 8 FHSTS BLACK ZP C 840459 SUPPORT HAT BRACKET D 405069 U BOLT 1 4 20 X 3 25 ZP E 405084 NUT 1 4 20 TOP LOCKING FLANGE F 403770 BRACKET WING MOUNT G 405124 PACK WEDGE MOUNT BRACKET W...

Страница 43: ...Cable Connections Remote Indicator Optional See J Box Connections Power Cord Scale Indicator Pin To 12VDC Power Supply 1 Red Terminal 2 Black Terminal 3 Orange Alarm Out 4 Blue Remote Input Digital I...

Страница 44: ...n of arrow when installing load cell Connect load cell wires to terminal blocks See Wire Color Tighten nuts Load cell Cable J Box Cable Connect to Indicator bottom panel J Box Illustrated for 4 Load C...

Страница 45: ...adingaccuracy Functions Communicateswithmultiple mixers Easilycall uprecipeswithout leavingloader Specification Internallymounted2 4GHz radios Upto1000footrange 24channels 12or24voltDCsystem Usewithin...

Страница 46: ...40smallremotedisplay with1 highnumbers RD2400Vbacklitremotedisplay with1 7 highnumbers RD2400Vbacklitremotedisplay w transmitterandinstalledreceiver RD2400backlitremotedisplay with 1 highnumbers RD240...

Страница 47: ...negative side When using a multimeter to check for voltage measure between pin 1 pos and pin 2 neg Meter should read between 10 5 and 14 5 volts DC if using a tractor power cord black wire is positive...

Страница 48: ...f each Load Cell and how much weight is over each Load Cell In general the number should be positive and stable 5 Stand or hang your weight over the connected Load Cell Record how much the weight incr...

Страница 49: ...gal for TradeindicatorsaremodifiedtocomplywithUSand Canadianregulatoryagencies Someofthesemodificationsare Load Cell Disconnect Sensor Indicatordisplays RANGE or RANGE withoutflashingloadwhencellsare...

Страница 50: ...nflashmemoryanddonotrequirebatteriestomaintaintheaudittrail values Changingany ofthefollowingparameterswillchangetheCalibrationevent countvalueorparameterauditeventcountvalue Thiswillvoidyour Legal fo...