Menus and Calibration
14
EZ2500 User’s Manual
D3895-US Rev A
SETTING
[display]
D.A.N
NO.
OPTIONS [displayed]
BOLD=DEFAULT
DESCRIPTION
MENU 2. CLOCK, PRINTER,
COMMUNICATIONS FEATURES
TARE AUTO
(tareap)
211
ON/
OFF
If ON -tare auto-prints
displayed weight.
ONE LINE PRINT
(Il prt)
212
ON/
OFF
If ON -indicator data prints on
one line.
AUTO PRINT
(aprint)
214
ON/
OFF
If ON -pressing keys auto-
prints weight values.
PRINT FORMAT
(prtfmt)
216
AUTO
WTONLY
DOWNLD
DT+TM
ID+TM
IDWTTM
ANIMAL
3200-A
3200-B
32-TMR
DATCH1
FDINFO
WTRCTM
EIDINF
EID
EIDVID
Select alternate & comma
(CSV) formats.
REMOTE
(REMOTE)
218
ON
/OFF
If ON indicator communicates
with cab control display
ZERO OUTPUT
(zerout)
219
Perform Zero/Balance for
SCOREM #11 weight output
and analog output (4-20mA)
SCALE NUMBER
(scl no)
231
Select scale number for cab
control communication
REMOTE
DISPLAY
(rmdisp)
234
EZ3MUX
EZ2
Select type of remote display
ANALOG LOW
WEIGHT
(LOW WT)
241
Enter analog weight value to
equal 4mA or 0 volts