background image

 

D3820-US Rev B 

June 21, 2013 

 

 

 

Cab Control 

Operators Manual 

 
 

 

 
 

 

Ft. Atkinson, Wisconsin  USA 

 

Pa

www.digi-star.com

 

Cab Control 2400 

Cab Control 3400 

Cab Control 3600 

nningen, The Netherland

Содержание Cab Control 2400

Страница 1: ...D3820 US Rev B June 21 2013 Cab Control Operators Manual Ft Atkinson Wisconsin USA Pa s www digi star com Cab Control 2400 Cab Control 3400 Cab Control 3600 nningen The Netherland ...

Страница 2: ...FORE CHARGING BATTERY OR WELDING 3 OPERATION 4 TURN ON INDICATOR 4 COMMUNICATE WITH DIFFERENT TRUCK 4 SETTING UP INDICATOR 5 SETTING UP THE CAB CONTROL 6 INSTALLATION 7 CAB CONTROL MOUNTING 7 CAB CONTROL CONNECTION 7 FCC NOTIFICATIONS 8 ...

Страница 3: ... charging battery or welding Damage may occur to indicator Note All illustrations are the EZ3600 Cab Control Keys used in this document are in same general location on all models If power supply low recharge battery turning off and lo pwr will display Recharg Note If lo bat displayed indicator power not Cab Control is low ...

Страница 4: ...TA and scale number Example SCL 1 Signal received display matches scale indicator and indicator is controlled by Cab Control Nodata Note For scale indicator operation refer to its manual 1 Pressing once checks which scale indicator is communicating 2 Repeatedly press until desired indicator number is displayed 0 Note If scale number is not displayed see setting up Cab Control page 6 1 ...

Страница 5: ...ber To set proper radio operation 1 3 Press and hold a then press holding both for 3 seconds 1 4 Press advances to Menu 2 2 5 Press advances to remote Press sets to on 6 Press saves setting and advance to scl no Press sets desired scale number 3 4 3 4 7 Press and hold and press to return to scale operation 8 Press Note For best performance with six or less indicators use numbers 1 6 5 6 5 ...

Страница 6: ...econds 2 setup 3 SETUP and BUZZER will show on display followed by current setting 4 5 6 7 4 Press toggles buzzer on off then press to advance to autoff 5 Press set to off 15 30 or 60 seconds Press 6 Press to enable or disable each of twelve available scales Press 7 After last scale set press to exit 6 4 5 ...

Страница 7: ...rol usually works fine if the scale indicator is mounted inside the truck cab and the Cab Control is mounted inside the loader at dashboard level Cab Control Connection Power obtained directly from 12 volt battery Stationary applications use120 VAC to 12VDC power cube that plugs into wall outlet Connect red wire from power cable to terminal of 12 volt battery and black wire to ground Cab Control T...

Страница 8: ...tion If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit ...

Отзывы: