20
General Specifications
Bluetooth version
4.0
Diode test
Test current of 0.9 mA maximum, open circuit
voltage 2.8 V DC typical
Continuity check
Audible signal will sound if resistance is
<35
Ω
(approx.); test current <0.35 Ma
Input impedance
>10 M
Ω
VDC and >10 M
Ω
VAC
AC response
True RMS
ACV bandwidth
50 to 400 Hz
Crest factor
≤
3 at full scale up to 500 V, decreasing
linearly to
≤
1.5 at 1000 V
Display
4000 counts LCD, backlighting and bar graph
Polarity
Automatic. No indication for positive;
minus (–) sign for negative.
Measurement rate
2 times per second, nominal
Overrange indication
‘OL’ display
Low battery indication ‘
’ is displayed
Auto power-off
15 minutes with disable feature
Battery
One (1) 9 V (NEDA 1604) battery
Enclosure
Double molded, waterproof
Shock (drop) test
6.5 ft (2 m)
Operating temp.
41 to 104
°
F (5 to 40
°
C)
Storage temperature
–4 to 140
°
F (–20 to 60
°
C)
Operating humidity
Max 80% up to 87
°
F (31
°
C) decreasing
linearly to 50% at 104
°
F (40
°
C)
Storage humidity
<80%
Operating altitude
7000 ft (2000 m) maximum
Dimensions
7
5
⁄
32
" x 3
7
⁄
32
" x 2
5
⁄
16
" (18.2 x 8.2 x 5.9 cm)
including holster
Weight
12.1 oz (342 g) including holster
Safety
This meter is intended for origin of
installation use and protected, against the
users, by double insulation per EN61010-1
and IEC61010-1 2 Edition (2001) to Category IV
600V and Category III 1000V; Pollution Degree
2. The meter also meets UL 61010-1, 2nd Edition
(2004), CAN/CSA C22.2 No. 61010-1 2nd Edition
(2004), and UL 61010B-2-031, 1st Edition (2003)
1065DGMAN_20250-64_Rev1.indd 20