5       MainTenance

The key feature of your Digga Cement Mixa is low maintenance. It contains no user serviceable parts, unauthorised disassembly will  

void warranty

●  

Make sure that all nuts and bolts are in place and properly tightened.

●  

Make sure that all other fasteners are in place and are performing their specified function.

●  

Make sure that all hydraulic fittings are tightened and that there are no leaks in any fittings or hoses.

●  

Make sure that all safety signs are in place, are clean, and are legible. (SEE THE SAFETY SIGN SECTION)

● 

Check for any Oil leaks

● 

Wear and tear on Pins, linkages, clips

●  

Replace any damaged parts and excessively worn parts.

● 

Use only manufacturer recommended replacement parts. Other parts may be substandard in fit and quality.

● 

Always wear safety goggles or glasses when inspecting equipment

SAFETY FIRST!! READ AND uNDERSTAND THE SAFETY INSTRuCTIONS 

BEFORE BEGINNING ANY DRIVE uNIT MAINTENANCE

BEFORE FIRST USE

BEFORE EACH USE

●  

Inspect the attachment for shipping damage. If damage does exist, do not operate until the damaged parts have been replaced  

 

or repaired.

● 

Oil needs to be changed after 12 months or 1000 hours then every 2 years there after. Oil changes must be performed by an  

 

Authorised Service Agent. Please Contact Digga for your nearest service location

EVERY 12 MONTHS

Escaping  fluid  under  pressure  can  have 

sufficient  force  to  penetrate  the  skin 

causing  serious  personal  injury.  Fluid 

escaping from a very small hole can be almost 

invisible.  use  a  piece  of  cardboard  or  wood, 

rather  than  hands  to  search  for  suspected 

leaks.  keep  unprotected  body  parts,  such  as 

face,  eyes,  and  arms  as  far  away  as 

possible  from  a  suspected  leak.  Flesh 

injected  with  hydraulic  fluid  may  develop 

gangrene  or  other  permanent  disabilities.

If injured by injected fluid, see a doctor at 

once. If your doctor is not familiar with this 

type of injury, ask him to research it 

immediately to determine proper treatment.

WARNING!  

    

CARDBOARD

HYDRAULIC HOSE

OR FITTING

MAGNIFYING GLASS

Always wear safety goggles or glasses when inspecting equipment

Содержание Cement Mixa

Страница 1: ...1 ...

Страница 2: ......

Страница 3: ...Only minor maintenance such as visual checking is required to keep it in top working condition Be sure to observe all safety precautions and maintenance procedures as described in this manual Contact your DIGGA dealer for any further information pertaining to this product or for further information on other products available in the DIGGA range 1 To the Purchaser ...

Страница 4: ...2 Product Manual Cement Mixa June 2009 Table of Contents 1 To the Purchaser 3 2 Table of Contents 4 3 Preparation for Use 5 4 installation and operating instructions 5 5 MAINTENANCE 8 Warranty 11 ...

Страница 5: ...on type of Drive unit the mixa is fitted to 3 Preparation for Use REF DESCRIPTION QTY A CEMENT MIX BOWL 1 B CEMENT MIXA ATTACHMENT CRADLE 1 C PINS 1 D LYNCH PINS OPTIONAL if not already purchased E Auger DRIVE UNIT 1 F Standard or SCS Cradle 1 A B C D E F C SCS PLease note Follow all safety precautions instructions as stated in your drive unit operators manual ...

Страница 6: ...t operators manual for installation before fitting the Cement Mixa onto the Auger Drive unit 1 Remove the shipping banding from around the cement mixa bowl and attachment cradle 2 Remove any DIGGA augers from the auger drive unit Ensure the auger is stored securely 3 Place cement mixa bowl vertical open end on the ground Raise the drive unit and crowd forward until the drive unit is hanging vertic...

Страница 7: ...MS IN PLACE SERIOUS DAMAGE OR PERSONAL INJURY COULD RESULT FROM LIFT ARMS ACCIDENTLY LOWERING REMOVAL AND STORAGE It is a requirement of the Australian Work place Health and Safety act 1995 that safe systems of work are employed when handling any attachments Complete compliance with Work place Health and Safety issues is compulsory and all due care and attention must be observed at all times in an...

Страница 8: ...aintenance BEFORE FIRST USE BEFORE EACH USE Inspect the attachment for shipping damage If damage does exist do not operate until the damaged parts have been replaced or repaired Oil needs to be changed after 12 months or 1000 hours then every 2 years there after Oil changes must be performed by an Authorised Service Agent Please Contact Digga for your nearest service location every 12 months Escap...

Страница 9: ...SQUARE HUB MI 000019 MIXA 3 5 CU FT CEMENT MIXa 2 HEX HUB MI 000018 MIXA 2 2 CU FT CEMENT MIXa 75MM SQUARE HUB MI 000017 MIXA 2 2 CU FT CEMENT MIXa 65MM ROUND HUB MI 000011 MIXA 2 2 CU FT CEMENT MIXa 57MM SQUARE HUB MI 000016 MIXA 2 2 CU FT CEMENT MIXa 2 HEX HUB MI 000015 E PDX PD7 Auger Drive Unit 1 F SWING CONTROL SCS2 FULL ASSEMBLY STANDARD 1 SC 000144 F SWING CONTROL SCSX2 FULL ASSEMBLY EXCAVA...

Страница 10: ......

Страница 11: ...4 ...

Отзывы: