background image

”RAIN OFF” (SHUTDOWN)

Press . The  sprinkler 

icon

appears. Press and icon
will appear. The controller is shut
down. Press 

to return to the

original programming. (The 

icon

will disappear.)

The shutdown mode causes the
valve to be suspended. The
programming, however, is
preserved.

SENSOR OPERATION

1. Press until appears 

next

to SENSOR.

2. Press 

to activate the sensor

in the irrigation program
selected.

* With the sensor circuit closed (i.e.,

the sensor detects the existence
of a defined program lockout
condition) the 

symbol blinks

on the display. In this situation,
irrigation will not take place
through the valve.

3. Press 

to disable the sensor.

The word “OFF” appears on the
display.

IRRIGATION WINDOW IN THE CYCLICAL PROGRAM MODE

The irrigation window is an advanced feature which enables
cyclical irrigation program operations (see Section B) to take place
only during a defined part of the day (window). The irrigation
window is defined as a part of a day (up to 23 hours), in the
cyclical irrigation mode only.

This function is useful when  irrigation is only required during the
hot hours of the day. For example, open window 9 am, closed
window 4 pm.

Make sure that 

appears on

the display

1. Press until  appears 

on

the display next to W.OPEN, with
the word OFF or last OPEN
WINDOW time setting displayed.

2. Press 

. The word OFF blinks on the display.

3. Press 

and 

to set the desired OPEN WINDOW time (pay

attention to the AM/PM designation).

4. Press until 

 appears 

on

the display next to W.CLOSE, with
the 12 am or the last close
window time setting displayed.

5. Press  

. The 12 am blinks on

the display.

6. Press  

and  

to set the desired CLOSE WINDOW time

(pay attention to the AM/PM designation).

To disable the irrigation window function

1. Press until  appears

next to OPEN WINDOW, with the
last OPEN WINDOW time setting
displayed.

2. Press 

. The irrigation window

open time blinks on the display.

3. Press 

until OFF appears next to 

.

VALVE IN OPERATION

icon will appear. If the 

flashes, the valve has not
opened, the possibilities are:

• Valve is in “short mode”. The

icon will flash once every 

1/2 second (120 times every minute).

BLINKING LOW BATTERY WARNING

A blinking battery icon
appears on the display
when the batteries are
weak. In this state, a
limited amount of energy
still remains in the
batteries for valve
operation, and they should
be promptly replaced.

Press any button after
replacing the batteries to resume irrigation controller activity.

Program data will be retained for approximately 20 seconds
during battery changing.

CONSTANT LOW BATTERY WARNING

When weakened batteries
are not replaced in a timely
manner, the battery icon
appears constantly. All
other display elements
disappear and all valves
are closed.

Replace batteries promptly,
then press any button to
resume irrigation controller
activity.

Program data will be retained for approximately 20 seconds
during battery changing.

NO PROGRAM

During “manual” irrigation
system operation via the
irrigation controller,
“no prog” appears on the
display, meaning that no
irrigation period has been
set for the valve. In this
case, the irrigation
controller “does not know” when to close the valve.

In this situation valve opening is disabled.

MAINTENANCE AND TROUBLESHOOTING

PROBLEM: 

Valve does not open

CAUSE: One of the following not entered: Watering time,

watering days, start time
SOLUTION: Check and program as required

CAUSE: Selector on “RAIN OFF” position

SOLUTION: Cancal RAIN OFF

CAUSE: Valve or connection faulty

SOLUTION: Check the valve or replace it

PROBLEM: 

Sensor icon constantly flashes on display and valve

does not open

CAUSE: Sensor is shorted

SOLUTION: Replace sensor or repair sensor connection

PROBLEM: 

Valve does not close, despite click heard during

activation

CAUSE: Dirt or stones in the valve.

SOLUTION: Clean the valve

CAUSE: Valve was opened manually

SOLUTION: Move the handle to automatic position

CAUSE: Valve faulty (torn diaphragm)

SOLUTION: Replace valve or part

CAUSE: 5mm seal (O-ring) is missing between the valve and

the valve coupling
SOLUTION: Install a new seal (O-ring)

PROBLEM: 

Display “disappears”

CAUSE: Batteries are weak

SOLUTION: Check the batteries 

PROBLEM: 

Water leak from solenoid-valve adapter

CAUSE: O-ring is missing

SOLUTION: See assembly and installation

DIG CORPORATION 3 YEAR WARRANTY

DIG CORPORATION warrants these products to be free from defects in material and

workmanship for a period of three years  from date of purchase. This warranty does

not cover damage resulting from accident, misuse, neglect, modification, improper

installation or subjection to line pressure in excess of 150 lbs. per square inch. This

warranty shall extend only to the original purchaser of the product for use by the

purchaser. This warranty shall not cover batteries or any malfunction of the product

due to battery failure. The obligation of DIG CORPORATION under this warranty is

limited to repairing or replacing at its factory this product which shall be returned to

the factory within one year after the original purchase and which on examination is

found to contain defects in material and workmanship.

DIG CORPORATION SHALL IN NO EVENT BE LIABLE FOR ANY INCIDENTAL OR

CONSEQUENTIAL DAMAGES OF ANY KIND; THE SOLE OBLIGATION OF DIG BEING

LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCTS. SOME STATES DO

NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL

DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.

Unattended use for prolonged periods without inspection to verify proper operation is

beyond the intended use of this product, and any damage resulting from such use

shall not be the responsibility of DIG CORPORATION. There are no warranties which

extend beyond the description on the face hereof. In the case of purchase of the

product for use other than, for irrigation purposes, DIG CORPORATION hereby

disclaims any implied warranties including any warranties of merchantability and

fitness for a particular purpose. In the case of the purchase of the product for

personal, family or household purposes, DIG CORPORATION disclaims any such

warranties to the extent permitted by law. To the extent that any such disclaimer or

implied warranties shall be ineffectual, then any implied warranties shall be limited in

duration to a period of one year from the date of the original purchase for use by the

purchaser. Some states do not allow limitation on how long an implied warranty lasts,

so the above limitation may not apply to you.

In order to obtain performance under this warranty, the unit must be returned to the

factory, along with proof of purchase indicating original date of purchase, shipping

prepaid, addressed as follows:

DIG CORPORATION, 130 Bosstick Blvd., San Marcos, CA 92069. Repaired or replaced

units will be shipped prepaid to the name and address supplied with the unit returned

under warranty. Allow four weeks for repairs and shipping time. Repair of damaged

units not otherwise within warranty may be refused or done at a reasonable cost or

charge at the option of DIG CORPORATION.

This warranty gives you specific legal rights, and you may also have other rights

which vary from state to state.

7

8

9

TO ORDER PARTS:

1-800-322-9146 FAX: 760-727-0282

130 Bosstick Blvd.
San Marcos, CA 92069

E

www.digcorp.com/asdig
e-mail: [email protected]

© 1999 DIG CORP 26-034

Отзывы: