2. conTroller mounTing
•… Select…an…indoor…location…near…a…120…VAc…outlet.…the…location…
should…be…protected…from…moisture…and…sunlight
•… remove…the…mounting…bracket…from…the…back…of……
the…controller
•… Place…the…mounting…bracket…slightly…below…eye…level.…Secure…
the…bracket…with…#5…or…6…x…1”…screws…(note:…If…installing…on…
drywall,…install…screw…anchors)
•… Align…controller…housing…with…mounting…bracket.…Slide…the…
controller…down…into…position…on…the…bracket.
DO NOT PLUG TRANSFORMER INTO POWER SOURCE UNTIL
THE CONTROLLER IS MOUNTED AND ALL VALVES HAVE BEEN CONNECTED.
3. back-uP baTTery insTallaTion
rotate…the…battery…compartment…cover…handle…to…the…11…o’clock…position…to…remove…
the…cover…(see…drawing).…Install…one…9-volt…alkaline…battery…into…terminal…clip…and…
insert…into…battery…compartment…and…replace…the…cover.……the…controller…display…
elements…will…briefly…appear.…When…the…display…blinks…
“12:00”,…the…controller…is…ready…to…program.
IMPORTANT: To replace the battery compartment
cover, insert it with the handle in the “11” o’clock
position to avoid possible cover guide
pin breakage.
the…battery…is…intended…for…irrigation…program…backup…
only.…during…electrical…outages…the…program…will…not…be…erased,…however,…valves…will…
not…operate.
4. connecTing valves and Trnsformer
1.…Install…control…wire…between…valve…location…and…controller.
2.…At…the…valve,…connect…the…common…wire…to…either…solenoid…wire…of…all…valves.…
connect…a…separate…wire…to…each…of…the…remaining…valve…wires…using…waterproof…
wire…splice…connections.
2
3.…remove…cover…from…controller…to…access…the…terminal…strip…area.
4.…connect…valves…common…wire…to…“c”…(common)…and…individual…valve…wire…to…
appropriate…valve…#…on…the…controller…terminal…(see…Figure…1).
5.…Insert…transformer…wire…through…the…hole…in…the…bottom…of…the…controller…and…
connect…the…wire…to…the…two…screws…marked…“Ac”.…(Polarity…does…not…matter.)
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
…
Do not plug transformer into power source until the controller is mounted.
5. connecTing a masTer valve or PumP sTarT relay
Mount…the…controller…10…to…15…feet…away…from…the…pump…start…relay…and…the…pump.…
notE:…to…operate…a…pump,…a…pump…start…relay…must…be…used.
connect…either…wire…from…pump…start…relay…to…controller…terminal…“M”,…connect…other…
wire…to…the…“c”…(common)…terminal.
Do not connect controller directly to pump start, it can damage the controller.
Connecting the controller to a pump is to be performed by a qualified
electrician only.
3
M
C
C
AC
AC
S
S
1
2
3
4
5
6
Transformer
120 VAC
Sensor
N.O.
Valves
M 1 2 3 4 5 6
figure 1