Yog’s E-PIPE one powered by dicodes
11
Switching off the device
In addition to the auto switch-off function, the user can also switch off the device
manually.
We recommend switching off the device before changing the battery or waiting for the
automatic switch-off, as in this case the statistics counters are saved. Otherwise, the
changes since the last saving will be lost when the battery is removed.
To switch off, wait until the "0" is displayed inverted and then press the key. Please note
that after an active switch-off (i.e. not auto switch-off), the device can only be switched
on again by briefly pressing the key five times.
Extended Functions Menu
The Extended Functions Menu offers three logically grouped sub-menus:
Heater Menu
➔
Settings related to the heater or coil
Mod Menu
➔
Settings for individual use and appearance
Value Menu
➔
Provides various statistics about of vaping
The Extended Functions Menu provides a variety of setting options, to give the user the
highest possible flexibility in customizing the settings to their preferences. Normally,
once the settings have been made, the user will rarely need to change the parameters.
To keep the main menu as short as possible, the advanced function menu was created.
The many options may scare off some users at first. But without the extended functions
menu, the device would not be able to meet all the different customer requirements.
Please take some time to familiarize yourself with the menu. We are sure once you get
an overview, customization will be a breeze.
Error Messages
If an error occurs, the device jumps directly to the error menu and displays the error
number and a mnemonic (short) description. The possible error messages are:
0 OvrVolt:
➔
The input voltage is too high. The E-PIPE one is prepared for operation
with one battery. If the input voltage exceeds 4.5 V, this error message
is displayed. Reduce the input voltage to the specified range.
1 ChkAtom:
➔
No atomizer detected or open coil.
2 TempRef:
➔
A problem occured while measuring the temperature reference.
3 N/A
4 OverCur:
➔
Short-circuit (current too high) or coil interruption (sudden burnout of
the coil at high power)
5 LowBat:
➔
The battery voltage under load has reached the minimum value set
under UbatMin.
6 EleHot:
➔
The electronics have heated up heavily and must cool down. This
error cannot occur during normal not occur during normal use.
7 TimeOut:
➔
The maximum draw time is limited depending on the power: max. 20
seconds for powers < 20W. Above 20W it decreases by 0.5 sec/W.
Above 40W, the maximum draw time is 10 seconds.
8 LowR:
➔
In bypass mode, the coil resistance is too low.