05 Main Menu (Page 7)
Extended Functions Menu
Heater Menu
Settings related to the heater or coil
Mod Menu
Settings related to the individual usage and appearance
Value Menu
Provides several statistics of vaping
The Extended Functions Menu provides three logically grouped sub-menues:
Error Messages
If an error occurs, the mod directly jumps to the error menu and displays the
error number and a mnemonic (short-term) description.
The possible error messages are:
The Extended Functions Menu offers a lot of setting options of the device, to provide the highest possible
flexibility for the user to individually adjust it to whatever preferences. Normally, once the settings were
made, the user will need to change the parameter rarely. In order to keep the main menu as short as
possible, the extended functions menu was created.
The many options may frighten some of the users initially. But without the extended functions menu
the mod would not be able to address all different customer requirements. Please take a bit of time to
get familiar with the menu. We are sure, as soon as you have gained an overview, the individual setup
is a walk-over. See the next pages for a more detailed explanation of the Extended Functions Menu.
0 OvrVolt:
The input voltage is too high. The Dani Box Micro operates with one battery.
If the input voltage exceeds 4.5V this error message is displayed. Reduce the input
voltage to the specified range.
1 ChkAtom: No atomizer detected or open coil.
2 TempRef: A problem during the temperature reference measurement occured
3 N/A
4 OverCur:
Short on coil or coil breakdown (open)
5 LowBat:
The battery voltage under load (with current drained from it) has reached the minimum
discharge level, defined with parameter UbatMin in the extended function mod-menu.
6 EleHot:
The electronics have heated up too much and needs to cool down. This error will not
occur with normal usage of the mod.
7 TimeOut: The maximum puff-time is limited depending on power. For a power <20W it is 20
seconds. Above 20W it decreases by 0.5seconds per Watt, above 40W it is 10 seconds.
8 LowR:
In Bypass mode the coil resistance is too low.
Illustration of the Dynamic Boost Operation
Содержание Dani Box Micro
Страница 1: ......