DicksonWare™ Software Specifications
Microsoft Windows® compatible
Allows for simple viewing and zooming of logged data
Easy set-up of Dickson Data Loggers including:
•
User selectable sample intervals from 10 seconds to 24 hours
•
Display temperature in °C or °F
•
Delayed logger start times
•
Logger data capacity can be set to wrap data or stop when full
•
Allow for real time monitoring and graphing.
•
Effortless exporting of data and graphs to other software
•
Data can be viewed in tabular (numeric/table) or graphical formats
Fast downloading of logged data - 30 seconds (typical) from full logger
Even shows battery power status for battery operated loggers
Specifications:
Compatible With:
Microsoft Windows® 95, 98, 2000, NT & XP
PC Requirements:
PC with 486 MHz or faster microprocessor, 4 MB RAM (A015), 16 MB RAM
(A016/A026/A025), 1 free COM (serial) port
with dedicated interrupt (A015/A025) or 1 USB root hub (A016/A026), CD drive, VGA monitor or
better
Cable Type/Length: 9 pin male D-shell to male 2.5mm stereo plug, 6’ long
Computer Interface:
RS-232 serial (COM) port or USB
DicksonWare™ Version Required (minimum):
9.0
DicksonWare™ SECURE Software Specifications
To ensure the authenticity, integrity and confidentiality of data, 21CFR Part 11 requires that electronic
records adhere to certain criteria. DicksonWare™ SECURE software collects data from our validated data
logger, creates detailed graphs and reports and contains the following features that comply with 21CFR11:
Password protection
Electronic signature consisting of User ID and Password
Collected data encrypted in secure files
Audit trail capability to identify date, time, user and action
For a complete 21CFR11 compliant package, order the following:
Appropriate Validated data logger
DicksonWare™ SECURE Software & Serial or USB Download Cable -
A025 or A026
Certificate of Validation/logger -
N520
Choose One Calibration Option Listed Below:
NIST Traceable Calibration 3-pt. (new unit) -
N300
NIST Traceable Calibration 1-pt. (new unit) -
N100
A2LA Accredited Calibration 3-pt. (new unit) -
N400
Note: SW400 Calibration Software may not be used with DicksonWare™ SECURE software.
Specifications:
Compatible With:
Windows® 95, 98, 2000, NT & XP
PC Requirements:
386MHz processor or higher, 4MB RAM, 1 free COM (serial) port, CD drive
Cable Type/Length:
A025: 9 pin male D-shell to male 2.5mm stereo plug, 6” long; A026: USB male
series “A” plug to 5-pin male series “B” mini plug, 6’ (2 meters)
Operating Range:
-20 to +135˚F, 0 to 95%RH (non-condensing)
Computer Interface:
RS-232 COM (serial port)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•