background image

POS-SCANNER

49-TPOSE-PSC-EN02

4

1.2.2. 

Leveling

Once the kit has been screwed, the scale must be leveled by means of the vial placed in the front of the
scale. To modify the leveling, the legs of the scale must be turned.

Turn the legs for levelling

Содержание POS-SCANNER

Страница 1: ...TEST AND ADJUSTMENT MANUAL POS SCANNER Ref 49 TPOSE PSC EN02...

Страница 2: ......

Страница 3: ...ING OF COMMUNICATIONS 14 5 4 1 Communication characteristics 14 5 5 COMMUNICATION PROTOCOLS 14 5 5 1 Selection of Protocol 14 5 5 2 Characteristics of the protocols 7 5 5 3 Operation 7 5 6 INFORMATION...

Страница 4: ......

Страница 5: ...TEST AND AJUSTMENT MANUAL 49 TPOSE PSC EN02 1 1 ASSEMBLY...

Страница 6: ...h two displays vendor and buyer including the connection cable between scale and display 3 Connection cable scale scanner Ref BB 5897 4 Screws 4 allen type n 4 screws 5 Communications cable wit PC or...

Страница 7: ...TEST AND AJUSTMENT MANUAL 49 TPOSE PSC EN02 3 Once the kit is placed in the right position it must be screwed by means of the 4 allen screws...

Страница 8: ...SC EN02 4 1 2 2 Leveling Once the kit has been screwed the scale must be leveled by means of the vial placed in the front of the scale To modify the leveling the legs of the scale must be turned Turn...

Страница 9: ...and verify the right leveling of the plate by means of an external level To fix the levelling of the plate use the plate leveling screws Once the plate is leveled the position of the screws must be fi...

Страница 10: ...ust be plugged in one side in the coonector marked as SCALE SCANNER of the scale and in the other side in the connector marked as AUX PORT of the scanner IMPORTANT This cable is polarised so there is...

Страница 11: ...splay scale is supplied mounted and plugged in the displays the other side must be plugged in the connector marked as SCALE DISPLAY of the scale 2 3 MAINS SUPPLY CONNECTION The connection of the scann...

Страница 12: ...lue in grams is shown in the weight display 2 The zero weight value in internal divisions is shown in the price per kilogram display This value is accompanied by a hyphen which is in the center segmen...

Страница 13: ...CPU This key can be pressed by removing a security covered screw and inserting a pointed object in the hole The following may be programmed 4 1 COUNTRY PROGRAMMING This parameter is only used for con...

Страница 14: ...NT This allows the adjustment to be modified according to the altitude at which the scale is to operate without carrying out a complete adjustment with calibrated weights Program a value between 0 and...

Страница 15: ...ighing platform and wait a few seconds for the weight to stabilize Press the key to begin the weight adjustment The display will show lines of hyphens while the adjustment is being done This process w...

Страница 16: ...HARGE The reference of the Telecharge cable is BB 5918 5 1 DESCRIPTION OF TELECHARGE CABLE BB 5918 5 2 CONNECTION FOR TELECHARGE The Telecharge cable Ref BB 5918 must be connected to the Telecharge co...

Страница 17: ...EN02 13 5 3 COMMUNICATIONS The cable to connect the scale to PC or POS has the reference BB 5896 and it must be plugged in the connector marked as SCALE COM of the scale L Never use a communications...

Страница 18: ...d 12 19200 7 1 Even 32 1200 8 1 No 13 19200 7 1 Odd 33 1200 8 1 Even 14 19200 7 2 Even 34 1200 8 1 Odd 15 19200 7 2 Odd 35 1200 8 2 No 16 4800 8 1 No 36 1200 7 1 Even 17 4800 8 1 Even 37 1200 7 1 Odd...

Страница 19: ...5 3 Operation Having configured the type of device with which communication is to be established simply effect the desired operation from the corresponding PC and the scales will automatically send t...

Страница 20: ...06h 01 0x30 y 0x31h EC 0x1Bh EX 0x03h WWWWW 5 digits for the WEIGHT PPPPP 5 digits for the PRICE IIIIII 6 digits for the SUM 5 7 2 Tpv Casio Ce Protocol Protocol Cash register Scales SX AK 1PPPPPCRLF...

Страница 21: ...WWWWWEIIIIIICCRLF Where 98 0x38h y 0x39h PPPPP 5 digits for the price C Checksum logical sum XOR of all previous characters CR 0x0Dh LF 0x0Ah 99 0x39h y 0x39h S Weight status S 0x30h Correct S 0x31h E...

Страница 22: ...0Dh LF 0x0Ah 5 7 7 Apollo Samsung Poland Posnet Poland Cash Register Protocol Protocol Cash register Scales Eq AK D1 SHSxSWWW WWWkgBccExET Where Eq 0x05h AK 0x06h D1 0x11h SH 0x01h SX 0x02h S Weight s...

Страница 23: ...x0Ah WWWWWW 5 digits for WEIGHT 0x2E Decimal point S 0x53h Weight status 00 0x30h 0x30h Whether correct weight status is activated KG 0x4Bh y 0x47h ETX 0x03h 4 3 12 Uniprox Bmc Ps 2000 Cash Register P...

Страница 24: ...PPECEX Set 2 Cash Register Scales ETSX03ECPPPPPPECTTTTEX Set 3 Cash Register Scales ETSX05ECPPPPPPECTTTTECMMMMMMMMMMMMMEX Using the different heading the protocol is developed in the same way for all...

Страница 25: ...0x2Eh 4 3 16 Nci Cash Register Protocol Protocol Cash Register Scales 1 Weight request W CR LF xx xxx Kg CR LF SH CR EX 2 Status request S CR LF SH CR EX 3 Zero setting of the scale Z CR LF SH CR EX 4...

Страница 26: ......

Страница 27: ...NT MANUAL 49 TPOSE PSC EN02 17 True copy of the manual deposited with notified body N 317 The information in this manual may be modified by the manufacturer without prior notice Ref 49 TPOSE PSC EN02...

Страница 28: ......

Отзывы: