background image

27

VI. MAINTENANCE

1. MAINTENENCE

All the components requiring maintenance are accessible
from the front of the appliance, after removing the control
panel and front panel. Disconnect the power supply before
opening the appliance

1.1 BRIEF TROUBLESHOOTING GUIDE

Even in normal appliance operating conditions, malfunctions
can occasionally occur.

-

The pilot burner of open burners does not light

Possible causes:

Insufficient pressure in gas pipes.

Nozzle blocked.

Faulty gas cock.

-

The oven pilot burner does not light

Possible causes:

Igniter not properly fixed or connected

The piezoelectric ignition or igniter cable are damaged.

Insufficient pressure in gas pipes

Worn nozzle

Faulty gas valve

-

The pilot burner goes out when the “pilot ignition” knob is
released

Possible causes:

The pilot bur ner is not heating the thermocouple
sufficiently.

Faulty thermocouple.

The gas cock and/or gas valve knob is not being pressed
enough.

Lack of gas pressure to the cock and/or valve.

Faulty gas cock or gas valve.

-

The pilot burner is still lit but the main burner does not light

Possible causes:

Loss of pressure in gas supply pipe.

Blocked nozzle or faulty gas cock or valve.

Gas outlet holes on burner clogged.

-

The oven temperature cannot be adjusted.

Possible causes:

Faulty thermostat bulb.

Faulty gas valve.

Faulty electric thermostat.

Electric safety thermostat tripped.

ABNORMAL OPERATION

Any of the following are considered to be abnormal operation

and may require servicing:

incomplete ignition of the burner;

yellow tipping of the burner flame;

burner failing to remain alight;

gas valves are difficult to turn;

burner exitinguished by operation of oven door.

In case the appliance fails to operate correctly, contact the

authorised service provider in your area.

INSTRUCTIONS FOR REPLACING COMPONENTS (to be
carried out only by an authorised installer).

Remove the front panel to access:

GAS COCK

Unscrew the pilot and thermocouple pipe, unscrew the
gas inlet and outlet connections.

For installation carry out the same procedure in reverse order.

PILOT BURNER, THERMOCOUPLE, IGNITER ASSEMBLY

To replace the igniter and thermocouple loosen the fixing
screws and remove the components.

To replace the pilot burner undo the gas pipe, remove the
pilot burner assembly

Replace the components, proceeding in reverse order to
refit the parts.

MAIN BURNER

Unscrew the gas connection from the nozzle holder

Undo the screws fixing the burner to the support

Remove the pilot burner assembly by undoing the screws

For installation carry out the same procedure in reverse order,
making sure that when positioning the burner the centering
pins, located at the back of the burner, enter their special seats

1.2 MAINTENENCE SCHEDULE

It is reccommended the appliance is inspected and
serviced by an authorized person at least every 12
months. For this purpose it is reccommended to draw up
a maintenece contract.

AUSTRALIA
For service and spare parts, please contact:

Electrolux - Tom Staddart Pty Ltd
Zanussi - JL Lennard Pty Ltd

Содержание 373000

Страница 1: ...Mod G17 2F4T N Production code 373000 10 2011 ...

Страница 2: ...INSTALLATION 19 1 REFERENCE STANDARDS 19 2 UNPACKING 19 3 POSITIONING 19 4 FUME EXHAUST AND VENTILATION 20 5 CONNECTIONS 21 6 SAFETY THERMOSTAT 22 7 BEFORE LEAVING 22 8 HANDRAIL 23 VI INSTRUCTIONS FOR THE USER 24 1 COOKTOP USE 24 2 OVEN USE 25 VII CLEANING 26 1 EXTERNAL PARTS 26 2 OTHER SURFACES 26 3 PERIODS OF DISUSE 26 4 INTERNAL PARTS 26 VIII MAINTENANCE 27 1 MAINTENANCE 27 ...

Страница 3: ...wer supplyvoltage V 230 230 230 400 440 400 440 400 440 Phases N 3 3 3 3 3 3 3 3 3 Frequency Hz 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 Cooktop hot plates 2 6 kW Nr 2 4 4 2 2 4 4 4 4 Cooktop hot plate max power kW 5 2 10 4 10 4 5 2 5 2 10 4 10 4 10 4 10 4 Oven max power kW 6 6 6 6 6 Nominal max power kW 4 5 5 2 9 10 4 14 6 16 4 4 5 5 2 4 5 5 2 14 6 16 4 14 6 16 4 14 6 16 4 14 6 16 4 ...

Страница 4: ...f it unless they are supervised or instructed in its use by a person responsible for their safety The appliance must be used by trained personnel Do not leave the appliance unattended when operating Turn the appliance off in case of fault or poor operation Do not use products even if diluted containing chlorine sodium hypochlorite hydrochloric or muriatic acid etc to clean the appliance or the flo...

Страница 5: ...local gas fitting regulations municipal building codes electrical wiring regulations local water supply regulations AS5601 gas installation health authorites and any other statutory regulations 2 UNPACKING IMPORTANT Immediately check for any damage caused during transport The forwarder is responsible for the goods during transport and delivery Inspect the packing before and after unloading Make a ...

Страница 6: ...ds The end of the exhaust pipe must be at least 1 8 m from the support surface of the appliance Note The system must ensure that a the fume exhaust is not obstructed b the length of the exhaust pipe does not exceed 3 m Use the adapter for connecting fume ducts of different diameters SUB CLAUSES 4 1 4 2 are not relevant for australian standard 5 CONNECTIONS Any installation work or maintenance to t...

Страница 7: ...ustment of primary air supply to burner s pilot nozzle s replacement minimum flame screw s replacement correct adjustment pilot s if necessary correct adjustment of supply pressure see technical data gas nozzles table apply sticker supplied with data of new gas type used 5 1 6 1 REPLACING THE MAIN BURNER NOZZLE cooktop Unscrew nozzle C and replace it with the corresponding nozzle for the selected ...

Страница 8: ...racteristics at least equivalent to H05RN F rubber insulated type cables Protect the cable section outside the appliance with a metal or rigid plastic pipe 5 2 3 CIRCUIT BREAKER Install a circuit breaker ahead of the appliance Contact opening distance and maximum leakage current must comply with current regulations 5 3 EQUIPOTENTIAL NODE AND EARTH CONNECTION Connect the appliance to an earth it mu...

Страница 9: ...ø6 holes at points A For 1200mm and 1600mm appliances also drill at point B 8 1 2 ZANUSSI HANDRAIL Screw supports D on handrail C and insert them at the holes prepared Insert reinforcement plate R and fix the supports S with the nuts and washer S C R 1a 8 1 3 ELECTROLUX HANDRAIL Fix supports A to the edge of the top at the holes prepared with screw B plate C and respective nuts and washer as shown...

Страница 10: ...reate problems in combustion Before lighting the burners make sure the flame spreaders are turned to the stop position 1 2 ELECTRIC MODELS Equipped with rapid heating electric hot plates each of 2 6 kW power To ensure long life of the hot plates observe the following use flat bottomed pots do not leave the hot plates switched on without pots or with empty pots do not spill cold liquids on the hot ...

Страница 11: ...ob I clockwise to position pilot Then press the knob down and turn it to position Off Note if removing knob L for cleaning always turn knob fully clockwise to the lowest setting and replace the knob so that the mark on the knob aligns with the lowest tempera ture marking Failure to replace the knob correctly will result in inaccurate oven temperature 2 2 ELECTRIC MODELS The heating elements are co...

Страница 12: ... affect the flame 2 OTHER SURFACES CAST IRON ELECTRIC HOT PLATES Clean the hot plates with a damp cloth then switch them on for a few minutes to dry rapidly lastly lubricate them with a light film of cooking oil DO NOT pour cold liquids on the hot plates while they are hot IMPORTANT With electric appliances make sure no water comes into contact with electrical components water penetration can caus...

Страница 13: ...lowing are considered to be abnormal operation and may require servicing incomplete ignition of the burner yellow tipping of the burner flame burner failing to remain alight gas valves are difficult to turn burner exitinguished by operation of oven door In case the appliance fails to operate correctly contact the authorised service provider in your area INSTRUCTIONS FOR REPLACING COMPONENTS to be ...

Отзывы: