background image

 

 

PHANTOM OWNER’S MANUAL 

(rev.2)

 

PAGE 15 OF 17 

between the two outside tubes.  You will need a Bias King or similar bias probe to check this.  
The bias trim pot, in the event you need to adjust bias, is located on the PCB. 
 

DIAGNOSING TUBE PROBLEMS 

 
Most tube amp problems relate to the tubes themselves.  After all, tubes are not the cutting 
edge of technological advancement.  DA tube choices are based both on tone and reliability.  
Nevertheless, tube problems are not infrequent occurrences.  But before you have to worry 
about  shipping  your  amp  for  repairs,  learning  to  diagnose  a  tube  problem  can  keep  you 
rockin’.   
 
If you read the preceding section, you’ve learned when and how to change your tubes.  We 
can not stress enough the importance of changing tubes to keep your amp running optimally.  
But even with regular maintenance, you can still have tube problems.  If you are playing out 
regularly, we suggest you keep a spare set of power tubes in your gig bag and maybe a few 
preamp tubes just in case. 
 
Crackling,  squeals  and  feedback,  excessive  noise  and  muddiness  or  low  output  are  all 
evidence of tube problems.   
 

Power tubes.

  The two main symptoms of a power tube problem are a blown fuse or a tube 

that begins to glow cherry red.  Either are typically indicative of a power tube failure.  Some 
failures  can  be  an  intermittent  short  and  some  can  be  a  tube  failure.    If  you  blow  a  fuse, 
replace it.  If it happens again, replace your power tubes.  If the tube glows cherry red, shut 
the amp  off  immediately.    As  power  tubes  are  wired  in  pairs,  a  failure  of this  nature  in  one 
tube  can  cause  the  other  tube  in  the  pair  to  fail  with  it.    If  you  encounter  this  problem,  as 
noted, shut the amp down immediately.  Wait a few minutes and fire it back up.  If it happens 
again, replace the tubes before using the amp again.  If not, you should probably still replace 
the tubes soon, but you should be able to operate the amp for a short period of time. 
 
In the event you have one or two power tube failures, you can replace that one tube or two 
tubes  to  get  you  through  a  show,  but  then  replace  all  four  with  a  matched  set  (see  the 
preceding section). 
 
If you are hearing noise and/or crackling, you can rule out (or in) a power tube with a simple 
test.  Gently tap on the power tubes, one at a time.  They should not make noise.  If noise 
changes with the tapping, you may have a failing power tube.  Always be prepared to shut 
the amp off in case you have a failing tube and the tap causes it to short.  If so, shut the amp 
off immediately and replace the tubes. 
 

Preamp  Tubes.

    Preamp  tubes  usually  cause  problems  through  noise  or  microphonics.    If 

noise,  you  will  hear  hiss,  crackling,  popping  or  similar  issues.    If  you  hear  squeal,  hum  or 
feedback,  it  is  typically  a  microphonic  tube.    Noise  from  microphonic  tubes  will  typically 
increase with a volume increase. 
 
To diagnose which tube is bad, the most important thing is to determine, if possible, whether 
the problem is on both channels or just one.  If you can tell that it is in both channels (even if 
only slightly on one channel), it is most likely V1, which is common to both channels.  A noisy 

Содержание Guitar Amplifier

Страница 1: ...OWNER S MANUAL...

Страница 2: ...d will give you years of enjoyment if it is well maintained Before you begin remember learn your amp and you ll be in the best position to achieve the tones and performance you want So please take the...

Страница 3: ...UICK START GUIDE 4 POWER STANDBY 5 DIALING IN 6 LOW FOCUS 6 EFFECTS LOOP 6 TONE VOLUME CONTROLS 8 CHANNEL 1 10 CHANNEL 2 11 SWITCHING 12 FRONT PANEL SWITCHING 12 PHANTOM CONTROLLER 12 ALTERNATE SWITCH...

Страница 4: ...ith 2 volumes for level adjustment to match volumes Rear panel low frequency 3 position adjustment switch allows for changing the amount and character of the bottom end effects both channels 2 switch...

Страница 5: ...ied technician Speakers Your DA product comes equipped with two speaker jacks Always ensure when connecting speakers that you use a high quality speaker cable Never use instrument cable to connect you...

Страница 6: ...ounds Effects loop Your effects loop is a series loop with a shorting jack in the Return position What does this mean to you When you plug a cable into the effects return it goes active When you unplu...

Страница 7: ...nate voltage should only be done by a qualified technician Following these guidelines will extend the life of your amp Enjoy QUICK START GUIDE So you re an experienced user you ve made your connection...

Страница 8: ...us knob resist the temptation to adjust the other knobs This will give you the best idea as to what effect that knob has on the overall tone of the amp Last two 6 Toggle back and forth between 2A and...

Страница 9: ...ch more low end You ll find however something you ve probably not ever had your low E will ring at the same volume level as your high E which is uncharacteristic of most high gain amps So you should f...

Страница 10: ...overall volume Let s do a test 1 Set your amp on Channel 2A 2 Set the Gain at 6 and the Volume at 4 It should be pretty loud 3 Now make sure the E Return control is set to 0 and plug a short patch ca...

Страница 11: ...nly go so fast So dime your gain But when it s not fast enough open up that governor by introducing some volume As you bring up the volume and heat up the channel mashing that gas pedal starts to real...

Страница 12: ...id range from 3 or 4 on the low range to 9 or 10 on the high NOTE TO US METAL GUYS Don t be afraid of your mids All the crunch in the world is fine so long as the audience can hear us Take out too man...

Страница 13: ...rst leaving the volume in place Now pick any spot on the gain setting above at least 3 and varying the volume controls For a punchier rounder blues tone you ll find lower gain settings with high volum...

Страница 14: ...producing more gain than tubes can handle or than you ll need Bringing gain levels to 10 can exceed the tube s capabilities depending on the circumstances which is why excessive gain will not likely p...

Страница 15: ...want one to be identical with just a touch more gain or just a touch more volume Set them the way you want them and switch away This feature is only to give you the player more options live Two rhythm...

Страница 16: ...G METHODS Your amp s TRS switching jack on the back panel allows you to control your amp with any device that conducts simple latching tip to ground switching functions e g the Diamond Amplification R...

Страница 17: ...anged every 6 months to a year If you don t play frequently they can last longer NOTE While power tubes can simply and suddenly fail they generally degrade over time So while your tubes may be working...

Страница 18: ...ows cherry red shut the amp off immediately As power tubes are wired in pairs a failure of this nature in one tube can cause the other tube in the pair to fail with it If you encounter this problem as...

Страница 19: ...lem is only on one channel or the other you ll know which tube is the problem If it s only on the clean channel it s tube V2 If it s on the crunch channel it is either V3 or V4 but most likely V3 NOTE...

Страница 20: ...DIAMOND AMPLIFICATION INC 5261 LANGFIELD RD HOUSTON TEXAS 77040 713 934 0100 TEL 713 934 0155 FAX www diamondamplification com...