Dialogic DM/V480A-2T1-PCI Скачать руководство пользователя страница 2

the board. 

5.

 

Using the slot’s board guides, insert the board’s edge 
connector into the bus slot. Press firmly until the 
board is securely seated in the slot. 

 

Installing a PCI Board

16-Bit

ISA Slot

32-Bit

PCI Slot

PCI

Board

Computer

Chassis

Remove

Cover

Plate

 

6.

 

Replace and tighten the slot’s retaining screw to 
secure the board firmly in the chassis (if applicable). 

7.

 

Connect external digital telephone cables to the 
RJ-48C jacks on the board bracket. The topmost 
RJ-48C jack is for trunk 1 and the second RJ-48C 
jack is for trunk 2. 

 

Network Interface

Cable Connector

RCV_RING
RCV_TIP
CHASSIS GROUND
XMIT_RING
XMIT_TIP
CHASSIS GROUND
CHASSIS GROUND
CHASSIS GROUND

1
2
3
4
5
6
7
8

Pinouts for the RJ–48C

Jacks on Bracket

Pin 1

1

2

3

4

5

6

7

8

 

8.

 

Repeat steps 3-7 for each additional board you are 
installing. 

9.

 

Use the CT Bus cable to connect the board(s) you 
are installing to other boards in the system. To 
preserve the electrical integrity of the CT Bus, use a 
CT Bus cable with the appropriate number of 
connectors (“drops”). It is recommended that no more 
than two connectors at either end of the cable be left 
unused.  

Note:  

 

10.

 

Your system may include both CT Bus and SCbus 
boards. To connect both board types, you must 
install a CT Bus/SCbus Adapter on one of the CT 
Bus boards in a system. See the CT Bus/SCbus 
Adapter Quick Install Card for installation details 
about the Adapter and the bus cables.  

11.

 

Install CT Bus Termination Jumpers only on boards 
located at each end of the CT Bus cable. See

 

the 

“Physical Description” section for jumper details. 

 

Note:
Your CT Bus cable may 
have a different number 
of connectors (drops). 

CT Bus

Cable

Installing the CT Bus Cable

Colored

Stripe

(Pin 1)

 

12.

 

Replace the computer’s cover when finished and 
reconnect the power cords. 

13.

 

Turn the computer’s power ON. 

CAUTION:  

If your BIOS is set to use Plug and Play 

technology and there are ISA boards in your system, an 
IRQ conflict can be created if a PCI board is assigned 
the same IRQ as an ISA board. This could cause the 
machine to stop responding. You can prevent this by 
entering the BIOS and reserving the appropriate IRQs 
(those used by your ISA boards) for ISA use only. 

 

After Installing the Hardware 

After installing the hardware, run the Dialogic

®

 

Configuration Manager (DCM) as described in the 
installation instructions included with the Dialogic

®

 

System Software to configure your system. 

For technical specifications and product information go 
to: http://www.dialogic.com/products.htm.

 

Warranty and Return Information 

Warranty Period 

For specific warranty information for this board, refer to 
the Warranty section of the Products page, located at 
this URL: http://www.dialogic.com/warranties/.  

Contacting Technical Support 

Dialogic provides technical support for its products 
through a network of value added distributors who are 
trained to answer technical questions on installing and 
configuring Dialogic

®

 products.  If you are unsure how 

to contact your support channel, please call Dialogic 
in the United States at 973-967-6600 (9am-5pm EST) 
and we will assist in obtaining the appropriate support 
channel.  Outside the United States please refer to 

http://www.dialogic.com/support/contact

 to obtain 

local contact information.  Dialogic also provides direct 
support via Dialogic

®

 Pro™ Services agreements.  For 

more details of direct support from Dialogic please refer 
to: 

http://www.dialogic.com/support/DialogicPro

Returning a Product 

To return a board for warranty repair or any other 
returns, please refer to the following: 
http://www.dialogic.com/support/hwfaults .                                

Sales Assistance 

If you have a sales question, please contact your 
local Sales Representative or the Regional Sales Office 
for your area. Address, telephone and fax numbers, are 
available at the Dialogic website located at: 

http://www.dialogic.com/contact.htm

 

To purchase Dialogic

®

 products, please refer to the 

following website to locate the appropriate supplier: 

http://www.dialogic.com/purchase.htm

All contents of this document are furnished for informational use only and are subject 
to change without notice and do not represent a commitment on the part of Dialogic 
Corporation or its subsidiaries (“Dialogic”). Reasonable effort is made to ensure the 
accuracy of the information contained in the document. However, Dialogic does not 
warrant the accuracy of this information and cannot accept responsibility for errors, 
inaccuracies or omissions that may be contained in this document.  

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH 
DIALOGIC

®

 PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL 

OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED 
BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT 
BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY 
WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED 
WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS 
INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A 
PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY 
INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY. 

Dialogic products are not intended for use in medical, life saving, life sustaining, 
critical control or safety systems, or in nuclear facility applications. 

It is possible that the use or implementation of any one of the concepts, applications, or 
ideas described in this document, in marketing collateral produced by or on web pages 
maintained by Dialogic may infringe one or more patents or other intellectual property 
rights owned by third parties. Dialogic does not provide any intellectual property 
licenses with the sale of Dialogic products other than a license to use such product in 
accordance with intellectual property owned or validly licensed by Dialogic and no 
such licenses are provided except pursuant to a signed agreement with Dialogic. More 
detailed information about such intellectual property is available from Dialogic’s legal 
department at 9800 Cavendish Blvd., 5

th

 Floor, Montreal, Quebec, Canada H4M 2V9. 

Dialogic encourages all users of its products to procure all necessary intellectual 
property licenses required to implement any concepts or applications and does not 
condone or encourage any intellectual property infringement and disclaims any 
responsibility related thereto. These intellectual property licenses may differ from 
country to country and it is the responsibility of those who develop the concepts or 
applications to be aware of and comply with different national license 
requirements.

  

Dialogic, Diva, Eicon, Eicon Networks, Eiconcard and SIPcontrol, among others, are 
either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be 
used publicly only with permission from Dialogic. Such permission may only be 
granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, 
Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be 
subject to full respect of the trademark guidelines published by Dialogic from time to 
time and any use of Dialogic’s trademarks requires proper acknowledgement.  The 
names of actual companies and products mentioned herein are the trademarks of their 
respective owners.

 

Отзывы: