![Dialog DA1468 Series Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/dialog/da1468-series/da1468-series_user-manual_2492947037.webp)
UM-B-074
DA1468x Range Extender Daughterboard
User Manual
Revision 1.1
17-Apr-2018
CFR0012
37 of 60
© 2018 Dialog Semiconductor
15 BLE Measurements
15.1 Basic Performance Measurements
All measurements reported here use the following parameters:
Operating Conditions:
●
T
= 21 °C
●
VBAT = 3 V
Equipment:
●
Signal analyzer: Rohde & Schwarz FSV Spectrum analyzer
●
R&S CBT - CBT go PC testing software
●
Agilent N6705B DC power analyzer
– Keysight 14585A Control and Analysis Software
Tools:
●
SmartSnippets
Toolbox v4.3.3.1378
●
SmartSnippets
Studio v1.3.2.636
●
SDK RF Tools Command Line Interface Application
Test Procedure:
●
The board is set to continuous modulated transmission mode for spectrum analyzer
measurements.
●
Continuous packet transmission mode was used for R&S CBT measurements.
Test Configuration:
All tests are performed with the following settings:
●
DCDC_V18_VOLTAGE=0x16 default value (0x5000008C).
●
R73=16.5 Ω. Sets the VCC2 level to 1200 mV.
●
RF_TX_PWR_REG = 2 (0x500020C0). Sets the DA14680/681 TX output power to -2 dBm.
Measurements:
●
Receiver sensitivity (section
15.1.1
)
●
Transmitter output power (section
15.1.2
)
●
Current consumption (section
15.1.3
)