9100FLM000906 REV B 

Page 5 of 8 
 

ProSite Floodlight for CID2/CIID1/CIID2/CIII

Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727 

Tel: +1 732 919 3119   Fax: +1 732 751 5778    www.dialight.com 

 

NOTE:  The  DALI  circuit  in  two  power  supply 
luminaires  are  already  internally  wired  as  a 
daisy  chain  to  allow  for  commissioning  and 
discovery.  The  Bus  wire  needs  to  be 
connected  to  the  DALI  terminal  block 
positions in the wiring compartment. 
 

 

 

NOTE:

 

Make  sure  luminaires  containing  two 

power supplies are grouped and scheduled 
together  for  the  luminaire  to  function  in  the 

correct manner.

 

 

WARNING:  Improper  installation,  operation, 
or maintenance of this luminaire may result in 
the  invalidation  of  the  warranty,  certificate, 
or declaration of conformity. 

 
Maintenance / Inspection 
This  LED luminaire  should  require  a  minimum 

amount  of  maintenance.  If  any  unforeseen 
repairs are required, please contact Dialight 
or its authorized representative. 

 

Within  the  scope  of  maintenance  or 
inspection  routine  the  following  should  be 

included: 
 

 

Protective  hoses  should  be  covering the 
connection cables. 

 

 

Cable entries must be free of corrosion. 

 

 

The lens should be cleaned periodically as 

needed to ensure continued photometric 
performance. Clean the lens with a damp, 
non-abrasive,  lint  free  cloth.  If  not 
sufficient, use mild soap or a liquid cleaner. 

 

 

Inspect the luminaire to ensure that it is free 
of any obstructions or contamination (i.e. 

excessive dust build up). Clean with a non-
abrasive cloth if needed. 

 

 

Perform visual mechanical and  electrical 

inspections  on  a  regular  basis.  We 
recommend routine  checks  to  be  made 
on  a  yearly  basis.  Frequency of  use  and 
environment should determine this. 

 
It is recommended to follow an Electrical 
Preventive  Maintenance  Program  as 
described  in  NFPA  70B:  Recommended 

Practice for Electrical Equipment. 
 

Repairs / Overhaul / Modification 
The equipment must be operated according 
to  the  intended  purpose  in  a  perfect  and 

undamaged condition. 
 

NOTE:  Should  the  luminaire  enclosure  be 
damaged, only a full luminaire replacement 
will  be  permitted.  In  case  of  doubt,  the 
equipment should be returned to Dialight for 
inspection/repair.  

 
Disposal & Recycling 
When  the  apparatus  is  disposed  of,  the 
respective  national  regulations  on  waste 

disposal should be observed. 
 
Secondary Retention Cable 
 

Part Number 

Description 

H6XCAB60 

Secondary Retention 
Cable, Stainless Steel, 60” 

H6XCAB72 

Secondary Retention 
Cable, Stainless Steel, 72” 

 

1.

 

Read  and  follow  all  instructions  in  the 

installation  manual  provided  with  the 
secondary retention cable. 
 

2.

 

Connect  the  safety  cable  to  one  of  the 

retention brackets on the luminaire. 

 
3.

 

When  using  a  safety  cable  for  secondary 

retention,  ensure  minimum  slack  in  the 
cable installation. The slack should be no 
greater than 1 ft. [0.3 m] 

 

NOTE:  Cable  type,  size,  material,  and 
attachment  method  to  meet  customer 
application  and  to  be  appropriate  with  all 
local and regional regulations. 

 

 

 

 

 

 

 

 
 

 

 

 

 

F1 Retention Bracket Locations 

F1 Retention 

Bracket 

F2 Retention 

Bracket 

F2 Retention Bracket Locations 

Содержание ProSite

Страница 1: ...www dialight com Important Information These instructions contain safety information read and follow them carefully Dialight will not accept any responsibility for injury damage or loss which may occ...

Страница 2: ...ngung und oder eines Sicherheitsnetzes entsprechend der Installationsumgebung Es ist die ausschlie liche Verantwortlichkeit des Vertragsnehmers Monteurs und oder Endkunden a die Eignung des Produkts...

Страница 3: ...patterns Once mounted the angle of the luminaire can be adjusted by loosening the M8 Hex Bolt on each side of the bracket When loosening do not back bolt out more than 5 full rotations When the desire...

Страница 4: ...he terminal block or on a label and are presented in the table below SYMBOL COLOR CONNECTION 120 277VAC GREEN YELLOW EARTH GROUND N WHITE NEUTRAL L BLACK LIVE 120 250VDC GREEN YELLOW EARTH GROUND N WH...

Страница 5: ...ation i e excessive dust build up Clean with a non abrasive cloth if needed Perform visual mechanical and electrical inspections on a regular basis We recommend routine checks to be made on a yearly b...