57
GB
CONNECTIONS
Connections must be conform to the applicable
electrical rules and standards.
Connect the 230 V device (maximum power
1000 W) to be controlled.
Connect the power supply cable (not sup-
plied).
Fix the cables to the wall using suitable
fixing collars (not supplied).
Important notes:
●
if you want to control a motor, a relay, a
transformer or a neon light, the output should
be protected using a resistor and a capacitor (
R :
wound resistor 22 ohms - 3 watts -
C :
interference-
suppression capacitor class X2, 250 volts AC,
2.2 microfarads)
not supplied,
●
if you want to control a class I device (device
requiring an earth connection), the earth-device
connection must be made.
3
2
1
507445
40001
07/95
R
C
2 , 2
µ
F x M K T S H H P F
2 5 0 V
230 V - 50 Hz
power supply,
protected and isolatable
Connection of the
230 V device to be
controlled
(max 1000 W)
230 V - 50 Hz
power supply
Motor, relay, neon,
transformer (max power
1000 VA)
Warning:
All connections must be made
with the 230 V power supply switched off
and in the order indicated.
1
3
2
Содержание RP550