INTENDED USE

The Megaruptor

®

 3 is intended for laboratory use. It is not suitable for clinical use. Use of the Megaruptor 3 in any 

manner other than as directed herein could cause harm to persons and may void the warranty. Diagenode will not be 
responsible for injury or damage resulting from improper use of the Megaruptor 3.

WARNING

Carefully read the following instructions before using your Megaruptor 3 to avoid the risk of personal injury and 
damage.

• 

Do not use the Megaruptor 3 for anything other than its intended use.

• 

After removing the packaging, make sure that the Megaruptor 3 is intact.

• 

Do not use the Megaruptor 3 in a cold room.

• 

Do not allow the Megaruptor 3 to be used by untrained individuals.

• 

Clean the Megaruptor 3 carefully and regularly with soft tissue and water.

• 

Do not use any accessories not recommended by Diagenode.

• 

Do not use the Megaruptor 3 if it is showing any sign of breakdown or malfunction.

• 

Do not attempt to dismantle or repair.

Содержание Megaruptor 3

Страница 1: ...Megaruptor 3 Sleek Innovative Unmatched Diagenode Shearing Machine ...

Страница 2: ...fidence in Diagenode We have designed this device using our higest level of knowledge in shearing so that it exceeds your expectations This device will serve your research needs for many years and will provide the best experience with long DNA molecules preparation ...

Страница 3: ...fore using your Megaruptor 3 to avoid the risk of personal injury and damage Do not use the Megaruptor 3 for anything other than its intended use After removing the packaging make sure that the Megaruptor 3 is intact Do not use the Megaruptor 3 in a cold room Do not allow the Megaruptor 3 to be used by untrained individuals Clean the Megaruptor 3 carefully and regularly with soft tissue and water ...

Страница 4: ...eight 6 kg with Cassette included 0 8kg Fragment Length Range Achievable 5 kb 100 kb Sample Volume Range 65 500 µl Sample Concentration Range 0 150 ng µl Throughput 1 to 8 samples in parallel Time per Run Variable depending on sample volume concentration and target size Shearing Consumables Megaruptor 3 Shearing Kit 16 samples Cat No E07010003 User Interface Touchscreen with Megaruptor software ...

Страница 5: ...Power Button Led Light Bar Touchscreen Lid Cassette Plug Removable Cassette Sample Insert Base unit ...

Страница 6: ...cols Record your protocol Information General information about your Megaruptor 3 Settings Visualize and change the parameters of the Megaruptor 3 Initialization Set the system to its 0 position DESCRIPTION Protocols Run a shearing experiment follow instructions Advanced Mode Access for administrators Modification Modify the parameters ...

Страница 7: ...of your samples The blue light means the system is waiting for the operator and is flashing if the system needs to be initialized The green light indicates the progression of the run The orange light means the protocol is on pause The red light indicates an alert message ...

Страница 8: ...Start and initialize the device 1 2 INSTRUCTIONS The initialization step must be performed if the icon is flashing Start the shearing experiment ...

Страница 9: ... 3 4 Or find your pre recorded shearing protocol on User protocols PROTOCOLS Standard Low volume High concentration Sample Concentration 0 50 ng µl 51 150 ng µl Sample Volume 100 500 µl 65 µl 200 500 µl Fragment Length Achievable 5 100 kb 12 75 kb 5 100 kb If the conditions are different from the above table further optimization steps are needed Please contact Diagenode https www diagenode com en ...

Страница 10: ...Sample preparation between 65 500 µl Spin your sample s DNA solution in the 0 150 ng µl range 5 6 Hydro Tube INSTRUCTIONS ...

Страница 11: ...ge 8 Insert the sample s in the cassette 1 to 8 samples Watch the video on our Diagenode Youtube channel How to set up your sample s Always set consumables with sample or empty at each extremity of the cassette Hydropore Syringe Hydro Tube Plug ...

Страница 12: ...Let your Megaruptor running 9 Collect your sample s 10 INSTRUCTIONS ...

Страница 13: ...If you have any question please contact the specialist at https www diagenode com en pages support ...

Страница 14: ...ly unnecessary MANUAL SAFETY APPROVAL Megaruptor 3 has been assessed and certified under the standards ENVIRONMENTAL PROTECTION Packaging materials contain recyclable materials Read the full manual https www diagenode com en p megaruptor 3 Tab Documents ...

Страница 15: ...purchaser of the product If a manufacturing defect arises and a valid claim is received within the warranty period Diagenode at its discretion will repair or replace the product in accordance with the warranty terms and conditions stated herein In case of repair or replacement of a product under warranty Diagenode will cover the expenses to return the repaired or replacement product This warranty ...

Страница 16: ... 2019 Diagenode Inc All rights reserved The content of this document cannot be reproduced without prior permission of the authors ...

Отзывы: