Step 5 — Select Model

When you start di-soric ID, the model menu will appear:

1. Click the button showing the ID-06 C-Mount.
2. Click 

OK

Note:

 You can also simply double-click the button showing 

your imager to make your selection.

3. Click 

Yes

 when the following dialog appears:

Note:

 If you need to select another model later, click the 

Switch Model

 button near the top of the screen or use 

Model > New Model

 in the menu toolbar.

Step 8 — Calibrate

Imager settings can be adjusted automatically for optimum    
performance by either the EZ Button or by 

di-soric ID

.

During the calibration routine, the imager will flash its Read  
Rate percent LEDs and illumination LEDs while searching   
camera settings and determining the best configuration for 
decoding symbol data. If unsuccessful, the imager will emit 5 
short beeps and stop searching.

Calibrate by di-soric ID

1. Click the 

Calibrate

 button.

2. The imager will search camera settings to determine the 

best configuration for decoding symbol data.
A successful calibration will display a green frame around 
the symbol in di-soric ID, and the following message will 
appear: “Uploading all reader parameters.” After a moment 
the symbol data will be presented in the field below the 
image display window.

Calibrate by EZ Button

1. Hold down the EZ Button for about two seconds and 

release when you hear 

two short beeps

. The

 20%

 and 

40%

 LEDs will illuminate.

2. The imager will search camera settings to determine the 

best configuration for decoding symbol data.

Note:

 To end all EZ Button functions, press the EZ Button 

once and quickly release.

Calibrate by Serial Command

Send 

<@CAL>

 from a terminal program to begin auto-calibration.

Step 6 — Connect

To connect using the Connection Wizard:

• Click 

Connect

 on the menu toolbar, and then select 

Connection Wizard

.

• Select 

RS-232

 or 

Ethernet

 to activate the appropriate display.

• Configure settings as required by the application, and click 

Connect

.

• When a connection is established, the green indicator in the status 

bar at the bottom right of the screen will be visible:

Important:

 The imager is in 

Continuous Read Mode

 by default. For 

best connection results, be sure that no decodable symbols are 
within the imager’s field of view while attempting to connect.

Step 9 — Test Read Rate

Read Rate

 indicates the number of successful decodes per second 

achieved by the imager. 

Test Read Rate by di-soric ID

1. Click the 

Test

 button to start the 

Read Rate

 test.

If a symbol has been successfully decoded, its data and related 
information will be presented in the field below the image display 
window. While the symbol is being decoded, the Read Rate 
LEDs will indicate the read rate percentage on the top of the unit.

2. Click the 

Stop

 button to end the Read Rate test.

Note:

 Read rate can also be tested using the Read Rate

 

interface 

in 

Utilities

.

Test Read Rate by EZ Button

1. To start the Read Rate test, hold down the EZ Button about 

three seconds until you hear 

three short beeps

. The 

20%

40%

and 

60%

 LEDs on the top of the unit will illuminate.

While the symbol is being decoded, the Read Rate LEDs will 
indicate the read rate percentage on the top of the unit.

2. To end the Read Rate test, press the EZ Button and quickly 

release.

Test Read Rate by Serial Command

You can also start a test with the 

<C>

 or 

<Cp>

 command and end it 

with the 

<J>

 command.

Step 7 — Locate Symbol

Locate by di-soric ID

• In 

di-soric ID

’s 

EZ Mode

, click the 

Locate

 button.

The symbol in the field of view will appear in the video view 
beneath the 

Locate

 and 

Calibrate

 buttons.

• Center the symbol in the imager’s field of view.

Important: 

The entire symbol should fall within the field of 

view (FOV) of the imager. The field of view is what appears in 

di-soric ID

’s 

Locate/Calibrate

 window in 

EZ Mode

.

• Click the 

Stop

 button to end the 

Locate

 function.

Locate by EZ Button

If you are not connected to a host computer, the EZ Button 
allows you to locate the symbol in the imager’s field of view.
• Hold down the EZ Button for about one second and release 

when you hear one short beep. The amber 

20%

 LED will 

illuminate when the symbol is located.

Note:

 To end all EZ Button functions, press the EZ Button 

once and quickly release.

Step 10 — Configure and Save

Click the 

App Mode

 button to make configuration changes.

The following modes are accessible by clicking the buttons at 
the top of the screen:

• Click the 

EZ Mode

 button to return to EZ Mode.

• Click the 

Autoconnect

 button to establish communication.

• Click the 

Send/Recv

 button to send or receive commands.

• Click the 

Switch Model

 button to open the model menu.

• Click the 

Parameters

 button to show the tree controls for 

Communication, Read Cycle, Symbologies, I/O Parameters, 
Symbol Quality, Matchcode, and Diagnostics.

• Click the 

Setup

 button to access the Camera Setup tree and 

the interfaces for Video, Evaluation, Calibration, Window of 
Interest (WOI), Configuration Database, Ordered Output, Output 
Format, and Dynamic Setup.

• Click the 

Terminal

 button to display decoded symbol data, 

and to send serial commands to the imager using text or macros.

• Click the 

Utilities

 button to show the tabbed interfaces for Read 

Rate, Counters, Device Control, Differences from Default, Master 
Database, and Firmware.

Saving Options

Send, No Save

. Changes will be lost when power is re-applied 

to the imager.

Send and Save

. This activates all changes in current memory 

and

 saves to the imager for power-on.