DHP Air Compressor Trouble Shooting Guide - Section 8

NOTE: IN ANY OF THE PREVIOUSLY LISTED SOLUTIONS YOU MAY SIMPLY LISTEN FOR
THE AIR LEAK. CAUTION SHOULD BE TAKEN WHEN CHECKING THE AIR COMPRESSOR
FOR AIR LEAKS AS THE DENTAL AIR COMPRESSOR MOTOR COULD BE HOT.  IF YOU
ARE AT ALL UNCOMFORTABLE WITH DIAGNOSING A PROBLEM REGARDING THE DHP
DENTAL AIR COMPRESSOR CONTACT DHP IMMEDIATELY!

Dental Air Compressor does not supply enough air  to one operator

y

1)  Verify by consulting the dental units owners manual that the dental unit is operating properly.
2)  If the dental unit is operating properly verify the dental unit in question does not have any
additional filtration system that may require maintenance.
3)  Check the dental unit junction and visually inspect for either air leak or ' kinked 'or bent hosing.
NOTE: IF ANY OF THE PREVIOUSLY LISTED SOLUTIONS DO NOT REMEDY THE PROB-
LEM CONTACT DHP IMMEDIATELY!

Dental Air Compressor does not operate-motor humming noise is evident

1)  The dental air compressor motor is frozen as a result of lack of oil.  Verify if the dental air
compressor head has sufficient oil by visually inspecting the motor oil site glass as per the dia-
gram in Section 6 (oil sight glass location).  DO NOT ATTEMPT TO OPERATE THE DENTAL
AIR COMPRESSOR FURTHER CONTACT DHP IMMEDIATELY AS YOU MAY DAMAGE THE
MOTOR BEYOND REPAIR.

Dental Air Compressor does not operate-motor humming noise is evident. (cont.)

2)  The dental air compressor motor does not have the proper electrical voltage.  Verify if the
dental air compressor is 120 volts or 240 volts and using the proper electrical testing equipment
verify the electrical source is sufficient.

Dental Air Compressor motor operates but does not provide any air

1)  The dental air compressor system has an open air line.  Turn on the compressor and listen for
the air leak. Verify and correct the problem.  Do not attempt to adjust any of the air lines on the
dental air compressor contact the DHP factory customer service representative for additional
information.
2)  The dental air compressor motor shaft has broken.  DO NOT ATTEMPT TO OPERATE THE
DENTAL AIR COMPRESSOR CONTACT THE  DHP  FACTORY CUSTOMER SERVICE REP-
RESENTATIVE IMMEDIATELY FOR ADDITIONAL INSTRUCTIONS.

The DHP dental air compressor has one function to supply clean dry air for use in a dental office
application.  The dental air compressor is simple by design, however complex in operation. The
DHP dental air compressor could be hazardous to work on.  If you are not confident in your ability
to trouble shoot any problem, it is strongly recommended that you contact a DHP factory cus-
tomer service representative for additional information.  Our factory trained customer service
representatives are available at 1-800-423-5657 between 7:00 am and 3:30 P.M. Pacific Stan-
dard Time.

Содержание 1 Horsepower

Страница 1: ...ompressor Owners Manual 1 Horsepower Manufactured at 250 E Harrison Street Corona 92879 USA Phone 800 423 5657 International Phone 909 549 1400 Fax 909 549 1411 Website WWW DHPDENTAL COM E MAIL Harry dhpdental com ...

Страница 2: ...to Rico 1 800 423 5657 Canada 1 800 423 5657 Mexico 095 800 423 5657 Customer Service DHP customer service in house technicians have a minimum of 10 years experience in the manu facturing installation and maintenance of the DHP Dental Air Compressor Approved Testing Laboratories ETL Testing Laboratories File Number ETL 82327 Canadian Standards Association File Number CSA 82327 Payment Procedures A...

Страница 3: ... maxi mum The dental office equipment room will require a minimum of 5 air changes per hour which can be met with a 50 CFM vent fan in a 5 x 5 x 9 room The DHP Dental Air Compressor can be located outside of the dental office however it is extremely important the air compressor be covered from the elements as well as have the proper ventilation as previously mentioned It is strongly recommended th...

Страница 4: ...ectrical panel fuse breaker not be used to activate the Dental Air Compressor as it will deterio rate the fuse and significantly shorten the lifespan of the fuse PLUMBING REQUIREMENTS AIR LINE A 1 2 copper male pipe thread fitting on the utility closet end of the air line to the operatories is required to attach the Dental Air Compressor supply line to NOTE The DHP Dental Air Compressor regenerati...

Страница 5: ...INSTALLED 2 With Dental Air Compressor crate on the floor use a knife to open the box Do not attempt to lift the Dental Air Compressor simply dislodge the cardboard crate from the wooden pallet 3 With the cardboard crate removed from the wooden pallet locate the four bolts attaching the Dental Air Compressor to the wooden pallet and using a 7 16 open wrench remove the bolts from the pallet 4 Caref...

Страница 6: ...Y DHP DENTAL AIR COMPRESSOR Electrical Connections 1 The DHP one horsepower Dental Air Compressor is shipped as a standard 120 volts unless it is specified in writing a 240 volt model is required The DHP two horsepower Dental Air Compressor is shipped as a standard 240 volts the two horsepower Dental Air Compressor is available in 240 volt only 2 A wiring schematic for the DHP one horsepower is sh...

Страница 7: ...pressor should operate cycle on when in use If the air compressor cycles on when dentist has not used any air out of the storage tank their may be an air leak in the air system If you notice any unusual noises or cycling problems contact DHP customer service immediately Weekly Maintenance Dental Air Compressor 1 The DHP Dental Air Compressor does not require any weekly maintenance however it is st...

Страница 8: ...ing Filter replacement Push Down Latch and Twist Lower Cannister 2 Unscrew Filter Element Make Sure O ring is Note Displaced 3 After Filter Element is re placed re insert Cannister and twist until locked Make sure cannister O ring is note dis placed ...

Страница 9: ...r defective electrical breaker fuse and it should be replaced as soon as possible by a licensed electrician 2 Electrical Source is intact dental air compressor has power A Turn off the electrical power to the dental air compressor and CAREFULLY FEEL THE SIDE OF THE DENTAL AIR COMPRESSOR MOTOR BE EXTREMELY CAUTIOUS AS IT MAY BE VERY HOT If the dental air compressor motor is hot contact DHP immediat...

Страница 10: ...LY AS YOU MAY DAMAGE THE MOTOR BEYOND REPAIR Dental Air Compressor does not operate motor humming noise is evident cont 2 The dental air compressor motor does not have the proper electrical voltage Verify if the dental air compressor is 120 volts or 240 volts and using the proper electrical testing equipment verify the electrical source is sufficient Dental Air Compressor motor operates but does n...