WOUND CARE SETS (supplied separately: available in singles and packs of 10)

•  Gauze Wound Care Set - portal drain (standard; large; abdominal)
•  Soft Foam Wound Care Set - portal drain (small; medium; large; x-large; abdominal)
Note: Other Wound Care Sets may be available; please contact Direct Healthcare Group for latest information.

ALSO AVAILABLE

300ml canister with solidifier; Spare battery; Y-connector x 5; Carry bag; IV pole attachment bracket

3.5 General Warnings, Cautions and Information

•  There are no special skills required to operate the power unit however, Negative Pressure Wound Therapy 

should only be used under the advice, recommendation and supervision of a licensed Physician and / or a 
registered nurse.

•  The medical professional is responsible for applying his/her best medical judgment when using this system. Prior to use, 

the medical professional(s) treating the wound must assess how to best use the system for an individual wound.

•  Select correct setting for therapy required. Care should be taken not to accidently change pressures once set as the 

efficiency of the therapy may be reduced. This could also be caused by pets, pests or children.

•  The electricity supply is of the type indicated on the power adapter.
•  Check the power adapter cord is free from damage and is positioned so as not to cause an obstruction, or injury, e.g. 

strangulation. Do not position the vacuum power unit or power adapter such that makes it difficult to disconnect the 
supply or drain plug.

•  Ensure the power adapter cord, drain tube or vacuum power unit cannot become trapped or crushed, e.g. via raising or 

lowering of bed or bed rails or any other moving object. All tubes must be free of kinks, twists, properly connected and 
positioned so as not to cause an obstruction or injury.

•  Do not place the vacuum power unit or power adapter on or near a heat source.
•  Never use the power adapter whilst placed on top of or near to material which is flammable or can be damaged by heat. 

(The supplied power adapters plug directly into the power source partly mitigating this issue).

•  The 

VENTURI

 COMPACT TG600/8 vacuum power unit must only be used with the approved power adapter supplied by 

Direct Healthcare Group (see Specification on page 12)

•  The 

VENTURI

 COMPACT NPWT system (Vacuum power unit and power adapter) is not used in the presence of 

flammable anesthetics or in an oxygen enriched environment.

•  No part of the medical device should be serviced while it is in use by the patient.
•  The medical equipment requires 5 hours to warm from the minimum storage temperature before it is ready for its 

intended use.

•  The medical equipment requires 1 hour to cool from the maximum storage temperature before it is ready for its intended 

use.

•  Electric shock hazard; do not remove back of power unit.
•  Refer servicing to qualified service personnel.
•  When servicing use only identical parts.
•  Suitable for continuous or intermittent use.
•  Not suitable for sterilisation.
•  The materials used in the manufacture of all components of the system comply with the required fire safety regulations.
•  Direct Healthcare Group advise against smoking whilst the system is in use, to prevent the accidental secondary ignition 

of associated items which may be flammable.

•  WARNING: No modification of this equipment is allowed. Do not use unspecified parts.
•  Choking may result from a child swallowing a small part that has become detached from the ME equipment.
•  A Wound Care Set must be used with the 

VENTURI

 COMPACT system to carry out NPWT.

•  Please refer to the Wound Care Set ‘Instructions for Use’ leaflet (supplied with Wound Care Set) for dressing application 

and setup. Note that the dressings in the set are sterile and for single patient / single use only, not intended for reuse.

D H G - H E A LT H C A R E . C O M

4

V E N T U R I

®

  C O M PA C T

Содержание TG600/08F

Страница 1: ...DHG HE ALTHCAR E C O M VENTURI Compact User Manual...

Страница 2: ...VENTURI COMPACT DHG HEALTHCARE COM...

Страница 3: ...NPWT 5 Getting Started 5 Operating the Vacuum Power Unit 5 5 Operation Guidelines 6 User Information 6 Operation Controls 7 User Selectable Functions 8 Setting Changing Power Unit Display Languages 8...

Страница 4: ...Warning Refer to instruction manual booklet Medical Devices Directive 93 42 EEC Medical Device Regulation 2017 745 North America ETL listed Class II Equipment Double Insulated Do not dispose of with t...

Страница 5: ...for closure by primary intention for wound management odour control exudate management etc Wounds which may benefit from the application of NPWT include pressure ulcers dehisced surgical wounds diabet...

Страница 6: ...acuum power unit or power adapter on or near a heat source Never use the power adapter whilst placed on top of or near to material which is flammable or can be damaged by heat The supplied power adapt...

Страница 7: ...nal s treating the wound must assess how to best use the system for an individual wound 1 Remove all packaging from the power unit and mains adapter NB The power unit internal battery may be mostly di...

Страница 8: ...t and continue NPWT 7 Canisters should be replaced as required or weekly To change canister make sure power unit is in stand by mode if still running press and hold the UNLOCK button followed by the R...

Страница 9: ...ower unit will then power off after 1 minute of inactivity If using mains power switch off by disconnecting power cable from power unit or turning off mains power VACUUM LEVEL Vacuum level can be adju...

Страница 10: ...ey to select this function c To select the required language press and hold the THERAPY MODE button until the language is displayed Releasing the THERAPY MODE button will then set the display for the...

Страница 11: ...s adequately or may interfere with device function Direct Healthcare Group recommends the use of TECcare CONTROL antimicrobial wipes and fluid to clean and decontaminate all products it supplies to he...

Страница 12: ...he canister is removed both of which cancels the message and sounder and returns the power unit to stand by mode Change canister as detailed on page 6 NB The Canister Full sounder can be silenced by p...

Страница 13: ...put Voltage 12V Nominal Vacuum Application Continuous default therapy or intermittent Pressure Range 10 to 180mmHg 0mmHg 20mmHg Fixed Internal Battery 3 7V 10Wh Lithium Ion Rechargeable Cell IP Rating...

Страница 14: ...ion Medical electrical equipment safety and essential performance IEC 60601 1 11 Home healthcare environment 8 4 Manufacturer s Guarantee The VENTURI COMPACT power unit is covered by a 24 month manufa...

Страница 15: ...e source of the interference by turning nearby or suspect equipment off and see if the interference effects stop In any such event the user is encouraged to try to correct the interference by one of t...

Страница 16: ...UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 Mains supply quality for the mains adapter should be that of a typical commercial and or hospital environment In the event of a mains interruption the...

Страница 17: ...in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cell...

Страница 18: ...nual was correct at the time of going to press However Direct Healthcare Group reserves the right to modify the specification of any product without prior notice in line with a policy of continual pro...

Страница 19: ...DHG HEALTHCARE COM USER MANUAL Notes 1 7...

Страница 20: ...et Swatar BKR 4013 Malta Direct Healthcare Group Ltd Withey Court Western Industrial Estate Caerphilly United Kingdom CF83 1BF T 44 0 800 043 0881 F 44 0 845 459 9832 E info directhealthcaregroup com...