background image

© 2009 DHD Deubner Hoffmann Digital GmbH

Series 52

52/RX Mixing Console

Installation Guide

Version: 1.1.0

Содержание 52/RX

Страница 1: ...2009 DHD Deubner Hoffmann Digital GmbH Series 52 52 RX Mixing Console Installation Guide Version 1 1 0...

Страница 2: ...r 1 2 About this Book 2 3 What is new in this version of the manual 4 4 Environmental Specifications 5 5 Assembling and Wiring the Hardware 6 6 1 System Wiring 9 Meaning of the Controller Module LEDs...

Страница 3: ...l is copyright of DHD It might be distributed and copied as long as it is copied completely as a whole and this copyright notice is included No part of this document may be copied or distributed witho...

Страница 4: ...00D DSP Frame is described in the Toolbox5 configuration software manual How to Use this Book The Navigation Tree You can find the navigation tree on the left hand side of the PDF document Via the ent...

Страница 5: ...llowed unconditional because otherwise hardware and software products data bases as well as persons may suffer a loss Important The demands and advices in this fields should be followed because these...

Страница 6: ...ble and may be changed without notice No liability will be accepted by the publisher for any consequence of its use Publication thereof does neither convey nor imply any license under patent rights or...

Страница 7: ...s or other industrial or intellectual property rights 4 Environmental Specifications In the following you can find some general advices concerning the environment of an 52 RX If these values and stand...

Страница 8: ...metal object heater rack to divert electrostatic charges immediately before you touch electronical components 5 1 System Wiring Note You need an RM4200D DSP Frame with at least one RM420 852 853 Comm...

Страница 9: ...notice No liability will be accepted by the publisher for any consequence of its use Publication thereof does neither convey nor imply any license under patent rights or other industrial or intellectu...

Страница 10: ...rame It is also possible to mount the PoE switch next to the console and to use a separate power supply For configuration and controlling processes as well as communication with other DHD Systems the...

Страница 11: ...Meaning of the Controller Module LEDs The meaning of the LEDs are identical for the RM420 852 and the RM420 853 Communication Controller modules Meaning of the LEDs of the RM420 852 and the RM420 853...

Страница 12: ...r 52 5083 power supply frames The maximum power consumption in total is 200W You may also use two 52 5047 power supply units for smaller mixers with redundancy option inside the 52 5081 or 52 5083 pow...

Страница 13: ...e under patent rights or other industrial or intellectual property rights Power wiring possibilities of the 52 4080 PoE switch Please use the following information to calculate the power consumption o...

Страница 14: ...or any consequence of its use Publication thereof does neither convey nor imply any license under patent rights or other industrial or intellectual property rights 5 2 1 Power Consumption Example 1 In...

Страница 15: ...r imply any license under patent rights or other industrial or intellectual property rights 5 2 2 Power Consumption Example 2 An example of a larger console with motorized faders and a central TFT dis...

Страница 16: ...tic discharge 6 Environmental Specifications 5 G general advices 5 General Information 6 H humidity 5 M Meaning of the Controller Module LEDs 9 motorized fader modules 13 N non motorized fader modules...

Отзывы: