background image

Introduction

Thank you for purchasing the AquaSolvo Eco 
Ambient Air Sterilizer. This device incorporates 
a 4-in-1 high efficiency particulate air (HEPA) 
filter with a hypochlorous acid (HOCl) 
generator to sterilize the air. It can efficiently 
filter indoor air, removing particulate matter 
with a diameter of less than 2.5 microns 
(PM2.5). It can also absorb harmful chemicals 
such as formaldehyde, smoke, volatile organic 
compounds (VOCs) and other harmful gases.
The AquaSolvo Eco Ambient Air Sterilizer 
is a comprehensive solution to remove the 
contaminants from the air you breathe.
 

There are two models of the AquaSolvo Eco 
Ambient Air Sterilizer:

 

AAHE-50XX04 (without WiFi)

 

AAHE-50XX04C (with WiFi)

Note: XX is the color code. The unit is available 
in a variety of colors. 
This is for model AAHE-50WC04
instruction manual.

Safety Instructions

READ THESE SAFETY INSTRUCTIONS BEFORE USE

When using electrical appliances, basic precautions should always be followed to reduce the risk of 
fire, electric shock, and injury to persons, including the following:

WARNING: to reduce the risk of fire or electric shock, do not use this device with any solid-
state speed control device.

 

!

Read all the instructions before operating the 
unit.

 

!

Place the unit on the floor/ground where it is 
unlikely to be bumped or overturned to avoid 
potential spills. 

 

!

DO NOT sit, stand, or place heavy objects on 
the unit.

 

!

The unit must only be used in the upright 
position.

 

!

Do not move the unit when operating.

 

!

When moving the machine, it must be 
powered off and moved carefully to avoid 
spilling the water inside. If water is accidentally 
spilled, please wipe it dry. If the machine is 
accidentally tipped over or falls, water in the 
HOCl generator will spill inside the machine. 
It is recommended to unplug the power cord 
and allow the water to completely dry before 
use. The recommended storage time is 7 days.

 

!

NEVER place liquid containers, including drinks 
on top of the unit. Spilling liquids into the unit 
can damage the machine and potentially cause 
a shock or fire hazard.

 

!

Children should not use this equipment alone. 
Keep the unit away from small children and 
pets.

 

!

Do not use the unit outdoors. 

 

!

NEVER use the unit unless it is fully assembled.

 

!

This product can only be used with the 
supplied accessories.

 

!

DO NOT allow foreign objects to enter 
ventilation or exhaust opening as this may 
cause electric shock or damage to the unit. 

 

!

DO NOT block air outlets or intakes.

 

!

Locate the unit near an outlet and avoid using 
an extension cord or power strip.

 

!

This appliance has a polarized plug (one blade 
is wider than the other). To reduce the risk of 
electric shock, this plug is intended to fit only 
one way in a polarized outlet. If the plug does 
not fit fully in the outlet, reverse the plug. If it 
still does not fit, contact a qualified electrician. 
DO NOT attempt to defeat this safety feature.

 

!

Ensure the electrical outlet used with the 
Sterilizer is not loose or damaged. A poor 
electrical connection can result in overheating 
and damage to the power cord. If the outlet 
needs to be serviced contact a licensed 
electrician for repairs.

 

!

ALWAYS turn the unit OFF and unplug from 
the wall outlet when not in use. 

 

!

To disconnect the unit, make sure it is powered 
OFF then grip the plug and pull it from the wall 
outlet. NEVER pull the cord to unplug it. 

 

!

Do not use any electrical appliance that has a 
damaged power cord or plug.

 

!

Do not use any electrical product that you 
believe may be faulty product, or that has been 
dropped or damaged in any way. 

 

!

Keep the power cord away from hot surfaces.

 

!

Do not route the power cord under carpet or 
cover it with carpet. Route the power cord to 
minimize the possibility that someone could 
trip over it.

 

!

Do not expose the unit to excessive moisture. 
Avoid operating it where it might come in 
contact with water, such as bathrooms, laundry 
rooms or other damp places.

1

2

When you are shopping for an air purifier, it is recommended to:

A. Refer to the suggested room size; and
B. Refer to the tobacco smoke, dust, and pollen Clean Air Delivery Rate (CADR) ratings/numbers, 
developed by the Association of Home Appliance Manufacturers (AHAM) .  According to AHAM, 
the higher the CADR number, the faster the unit filters the air.  For more details, please refer to 
https://ahamverifide.org/ahams-air-filtration-standards/. AquaSolvo units are independently tested 
for common sources of indoor air pollution, i.e., tobacco smoke, dust, and pollen, and have received 
an individual CADR rating for each air pollutant. 

SUGGESTED ROOM SIZE:

460 Square feet/ 43 Square meter

THIS UNIT’S CARD RATINGS:

Tobacco Smoke: 296.4
Dust: 293.8
Pollen: 310.8

Содержание AquaSolvo AAHE-50WC04

Страница 1: ...voTM Eco Ambient Air Sterilizer INSTRUCTION MANUAL AAHE 50WC04 www DHLifelabs com AquaSolvo HOCl technology TM Filter Sterilize Smart Control MADE IN CHINA EPA Est No 99117 CHN 1 FDA Registered No 301...

Страница 2: ...fety Instructions 2 Product Overview 4 How It Works 4 Product Specifications 5 Unpacking and Setup 6 Operation Instructions 7 Using the Remote Control 10 Filter Replacement 11 Troubleshooting 12 Custo...

Страница 3: ...ssembled This product can only be used with the supplied accessories DO NOT allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the unit DO NOT...

Страница 4: ...The HOCl generator assembly is in the upper chamber The bottom chamber is concealed by a magnetically attached screen and houses the 4 in 1 HEPA filter The top chamber is concealed by a second screen...

Страница 5: ...on filter element to minimize possible contamination 9 Remove the cold evaporation filter by unscrewing it from the generator 10 Fill the generator with tap water to the MAX water level 800ml 27 05oz...

Страница 6: ...green with sound alert pls follow the operating alerts in page 9 for the operation action When the salt level is too low the indicator will display green with sound alert pls follow the operating ale...

Страница 7: ...ashing red sound alarm then stop working Internal motor error Flashing red sound alarm the unit keep working Air quality sensor error Using the Remote Control The Remote Control duplicates the functio...

Страница 8: ...ottom cover from the unit 3 Remove using the pull tabs and replace the replacement 4 in 1 HEPA filter into the Sterilizer main body NOTE Ensure that the pull tabs are facing outward to facilitate filt...

Страница 9: ...jurisdiction This warranty applies only to the original purchaser of this product from the original date of purchase At its option D H will repair or replace this product if it is found to be defectiv...

Страница 10: ......