Systems,
L.L.C.
MS
2000
MiniSteam Residential
Owner’s Manual
Your MiniSteam humidifier has
one of the most advanced
controllers of any humidifier. It
automatically controls drain and
fill rates for the most efficient
operation possible.
The front of the controller provides
a graphic to show unit operation,
and three buttons to control
functions.
Setting Maximum Steam Output:
Press the UP key (#2 fig 29) until
the appropriate LED on the output
graph lights up. Once for 30%,
two times for 50%, three times for
75%, and four times for 100%.
This setting can be used to reduce
the output of the humidifier for
applications where the full output
may not be needed.
16
The MiniSteam Controller
The controller parts are:
1. RESET button to reset alarms. When an alarm
occurs, the LEDs will blink in a certain way (see the
trouble-shooting section of this manual), and the
RESET button will glow red.
2. Increase capacity button. Pressing this button
increases the capacity of the humidifier in
increments.
3. DRAIN button for manual drain selection.
Push and hold to force the unit to drain all water.
4. 30% steam output level indicator.
5. 50% steam output level indicator.
6. 75% steam output level indicator.
7. 100% steam output level indicator.
8. Unit humidifying indicator.
9. High water level indicator.
10. Unit filling indicator.
11. Unit draining indicator.
Figure 29