background image

1

2a

2c

2b

3

4a

4b

Operation

             PRESFLO

®

 is switched off.

Press briefly 

or 

hold down

= nothing happens

Power is restored

 = PRESFLO

®

 

resumes NORMAL SERVICE and 
starts the pump (if necessary).

No power supply

              The system is pressurised. 
              All taps are turned off. There is 
              no demand for water. 
PRESFLO

® 

detects an assembly pressure 

higher than that of the start-up pressure 
(Pm) and no flow.

Press briefly

 = the pump is 

started manually and runs for 
a few seconds before stopping 
again. 

Hold down

 = lthe pump is put STAND-

BY. For instructions on how to reactivate 
the pump, see point 3.

A tap is turned on

 = as soon as the 

pressure falls below the start-up pressure 
(Pm), the pump is started.

NORMAL SERVICE: the pump is inactive.

                               The pump has been 
                               stopped manually. 
                               The pump will 
remain inactive until a new 
command is given.

Press briefly

= nothing happens.

Hold down

= the pump resumes NORMAL SERVICE. 
See points 2a - 2b.

                              The system has just 
                              ceased to require  
                              water. All taps are 
closed. The pump is still in operation. 
The system is pressurized. PRESFLO

®

 

detects a system pressure higher than 
the start-up 
pressure (Pm) and no flow.

Press briefly 

or 

hold down

 = 

the pump is stopped and put in 
STAND-BY
To reset see point 3.
If the absence of flow lasts for a few 
seconds the pump is stopped

STAND-BY

NORMAL SERVICE: pump during shutdown

                                See NOTE 1)
                                PRESFLO

®

 has       

                                detected that the 
pump is dry running and has therefore 
stopped it TEMPORARILY.

Press briefly

 = the pump is started and 

manually and resumes NORMAL SERVICE. 
See points 2a - 2b.

Hold down

= the pump is put STAND-BY. 
For instructions on how to 
reactivate the pump, see point 3. 

ERROR: stopped temporarily due to DRY RUNNING

              The assembly requires water. 
              One or more taps are turned on.  
              PRESFLO

®

 detects a flow; the 

assembly pressure is normally higher 
than the START-UP pressure, but it may 
also be lower. 

Press briefly

 or 

hold down

= the pump is stopped and put 
STAND-BY. 
For instructions on how to reac-
tivate the pump, see point 3.  

The taps are turned off

 = Sif there is 

no flow for a few seconds, the pump is 
stopped. 

NORMAL SERVICE: the pump is running

                                    (see NOTE 2)     
                                    PRESFLO

®

 has 

                                    detected that the 
pump starting-up too often and has therefore 
stopped it TEMPORARILY.

Press briefly

 = the pump 

is started and manually and 
resumes NORMAL SERVICE. 
See points 2a - 2b.

Hold down

= the pump will not restart and goes OUT 
OF ORDER. The pump is put STAND-BY. For 
instructions on how to reactivate the pump, 
see point 3.
 

ERROR: temporary shut down due to FREQUENT 
START UP

= Off

= On

= Flashing

Содержание PRESFLO

Страница 1: ... relevant regulations DGFLOW shall not be held lia ble for any damage relating to or resulting from an improper use of the product or for any damage relating to or resulting from servicing or repairs carri ed out by unqualified personnel and or with non OEM spare parts The warranty which is valid for 24 months from the date of purchase will no longer be applicable should the product suffer damage ...

Страница 2: ...mp and indicates a dry running error message Attention When the pump is star ted for the first time it may have to be run for longer in order to complete the priming procedure Press the STOP RESTART button to restart the pump and complete the priming procedure Motor Line Nut Seal Cable bushing Attention The cable bushings and circuit board cover must be properly assembled and secured in order to g...

Страница 3: ...stopped and put in STAND BY To reset see point 3 If the absence of flow lasts for a few seconds the pump is stopped STAND BY NORMAL SERVICE pump during shutdown See NOTE 1 PRESFLO has detected that the pump is dry running and has therefore stopped it TEMPORARILY Press briefly the pump is started and manually and resumes NORMAL SERVICE See points 2a 2b Hold down the pump is put STAND BY For instruc...

Страница 4: ...start up pressure Pm for the chosen application Relocate PRESFLO to another position Install a model with a higher start up pressure Pm Faulty electrical connections or pump out of service Check the electrical connections and that the pump is working PRESFLO STAND BY Reset PRESFLO See Operation point 3 PRESFLO in temporary shut down due to DRY RUNNING due to lack of water Wait for the automatic re...

Отзывы: