Operation

          PRESFLO

®

 is switched off.

Press briefly 

or 

hold down

 = 

nothing happens

Power is restored

 = 

PRESFLO

®

 resumes NORMAL 

SERVICE and starts the pump (if 
necessary).

No power supply

          The system is pressurised. 
           All taps are turned off. There is no 
demand for water. PRESFLO

® 

detects an 

assembly pressure higher than that of 
the start-up pressure (Pm) and no flow.

Press briefly

 = the pump is 

started manually and runs for 
a few seconds before stopping 
again. 

Hold down

 = lthe pump is put OUT OF 

SERVICE. 
For instructions on how to reactivate the 
pump, see point 3.

A tap is turned on

 = as soon as the 

pressure falls below the start-up pressu-
re (Pm), the pump is started.

NORMAL SERVICE: the pump is inactive.

                            The pump has been 
                            stopped manually. 
The pump will remain inactive until a new 
command is given.

Press briefly

= nothing happens.

Hold down

= the pump resumes NORMAL 
SERVICE. See points 2a - 2b.

OUT OF SERVICE

                            PRESFLO

®

 has 

                            detected that the 
pump is dry running and has therefore 
stopped it TEMPORARILY.

Press briefly

 = the pump is started 

and manually and resumes 
NORMAL SERVICE. See points 
2a - 2b.

Hold down

 = the pump is put 

OUT OF SERVICE. For instructions on 
how to reactivate the pump, see point 3. 

ERROR: stopped temporarily due to DRY RUNNING

          The assembly requires water. 
          One or more taps are turned on. 
PRESFLO

®

 detects a flow; the assembly 

pressure is normally higher than the 
START-UP pressure, but it may also be 
lower. 

Press briefly

 or 

hold down

= the pump is stopped and put 
OUT OF SERVICE. For instruc-
tions on how to reactivate the 
pump, see point 3.  

The taps are turned off

 = Sif there is 

no flow for a few seconds, the pump is 
stopped. 

NORMAL SERVICE: the pump is running

                            PRESFLO

®

 has 

                              detected that the 
pump starting-up too often and has there-
fore stopped it TEMPORARILY.

Press briefly

 = the pump 

is started and manually and 
resumes NORMAL SERVICE. See 
points 2a - 2b.

Hold down

 = the pump will 

not restart and goes OUT OF ORDER. 
The pump is put OUT OF SERVICE. For 
instructions on how to reactivate the pump, 
see point 3.
 

ERROR: temporary shut down due to FREQUENT START UP

ERROR: stop due to overload.

                            PRESFLO

®

 has 

                            detected a current 
exceeding the max. allowed and has the 
pump stopped.

Press briefly

 = the pump is started 

and manually and resumes 
NORMAL SERVICE. See points 
2a - 2b.

Hold down

 = the pump is put 

OUT OF SERVICE. For instructions on 
how to reactivate the pump, see point 3.  

          The system has just ceased to require 
          water.  All taps are closed. The pump 
          is still in operation. The system is 
pressurized. PRESFLO

®

 detects a system 

pressure higher than the start-up 
pressure (Pm) and no flow.

Press briefly

 or 

hold down

 = 

the pump is stopped and put in 
STAND-BY. To reset see point 3.
If the absence of flow lasts for a 
few seconds the pump is stopped.

NORMAL SERVICE: pump during shutdown

= Off

= On

= Flashing

Содержание PRESFLO MULTI

Страница 1: ...nic components PRESFLO can only be used with single phase pumps Working area Flow rate Pressure Shut off flow rate Start up pressure Qa Pm Safety regulations Before installing or using PRESFLO read this manual carefully and thoroughly The pump should be installed and serviced by qualified per sonnel responsible for making the hydraulic and electrical connections in compliance with the relevant reg...

Страница 2: ...It occurs when there is no water After 15 seconds PRESFLO stops the pump and indicates an ERROR message PRESFLO AUTOMATICALLY tries to resume NORMAL SERVICE at intervals of increasing time 1 15 30 60 minutes and successively once every hour 24 H for AU NZ If PRESFLO detects any pressure and or flow NORMAL SERVICE is resumed otherwise the pump is stopped again until the next attempt is made A MANUA...

Страница 3: ... turned on PRESFLO detects a flow the assembly pressure is normally higher than the START UP pressure but it may also be lower Press briefly or hold down the pump is stopped and put OUT OF SERVICE For instruc tions on how to reactivate the pump see point 3 The taps are turned off Sif there is no flow for a few seconds the pump is stopped NORMAL SERVICE the pump is running PRESFLO has detected that...

Страница 4: ...be adjusted continuously from 4 to 12 A trimmer B 4 When you finish adjustment close the cover CODE V Hz I max B V00103101 230 50 60 16 A SN 1506003 1 2 3 6 5 4 8 7 Exploded view of spare parts Attention when orde ring spare parts always state the position n from the diagram below and the product code number found in the pressure flow regulator technical data table Article Version Dimensions Off F...

Отзывы: