background image

 

 

 

Ultrasonic Thickness Gauge 

 

DC-2000C series 

 

 

Instruction Manual 

 
 

 

 
 
 
 

V. 7.11 

 
 

Содержание DC-2000C Series

Страница 1: ...Ultrasonic Thickness Gauge DC 2000C series Instruction Manual V 7 11...

Страница 2: ...m value measurement 8 8 4 1 3 Difference measurement DC 2020C 8 8 4 1 4 Average mode DC 2020C 8 8 4 1 5 Limitation setting DC 2020C 8 8 4 1 6 Scan DC 2020C 9 8 4 2 Velocity Rate 9 8 4 2 1 Materials 9...

Страница 3: ......

Страница 4: ...mics glass and any other good ultrasonic wave conductor The DC 2000C series accurately displays readings in either inches or millimeters 2 Technical Specifications Measurement range 0 65mm 400 0mm Res...

Страница 5: ...tteries Do not apply Build in calibration block with 4mm Cable DC 2020C Carrying case 1PC Operation manual Certificate 4 Overview the Display Unit 1 LCD Screen 2 Key Pad 3 Battery Pack 4 Probe socket...

Страница 6: ...operation Menu Confirm Key Press this Key to confirm the selection Up Arrow Achieve switch among the menu options in the menu operation Backlight Key Press this key to switch on or off the backlight...

Страница 7: ...ss this key to switch on or off the backlight Under the measurement Down Arrow Achieve switch among the menu options in the menu operation Calibration Put the probe in the air press this key to comple...

Страница 8: ...ies according to the standard delivery table in chapter 3 If user finds it is not the same as the table listed please contact the manufacture in time If the instrument is damaged please do not use it...

Страница 9: ...Hz 0 65 20mm 60 Used in the measurement of thin wall thickness and small curvature surface D2012 2 0MHz 2 0 400mm 60 Used in the measurement of coarse particles such as cast iron D5113 5 0MHz 2 0 200m...

Страница 10: ...trument will does not work normally and displaying Error 8 2 Probe Zero The gauge does an automatic zeroing of the probe thus eliminating the need for an on block zero Switch on the instrument then th...

Страница 11: ...ed point It is suitable for testing the curvature surface or needs to get the minimum value which is widely used in the thickness measurement of pipeline Notice It is not recommended to use this funct...

Страница 12: ...Directly select preset material velocity 2 Input the new velocity which is not preset into the menu 3 Get the accurate sound velocity of the workpiece which the thickness is known 8 4 2 1 Materials T...

Страница 13: ...ent Owing to the workpiece that is made from various materials and even the same material with different content and processing technology the sound velocity changes and this change causes measuring e...

Страница 14: ...0 series provides 4 locations to store new velocities 8 4 3 Resolution Press key into Resolution Press or to set resolution and unit 1 0 1 mm 2 0 01 mm 3 0 01 in 4 0 001 in Press key to enter confirm...

Страница 15: ...selected item press to confirm 8 4 5 1 Memory unit The gauge has a memory capacity of 5 200 test results The memory is composed by alphabet A Z location number There are maximum 200 test results in e...

Страница 16: ...ory Delete Memory Press to confirm Press or to select Yes or No Press to confirm the delete 8 4 5 4 Data Transfer Turn on the main unit and Keep the gauge under measurement interface Then connect PC w...

Страница 17: ...and stable measuring So for different measured objects and different measuring environment users should adjust the work status of the instrument to meet more measurements For many materials and measur...

Страница 18: ...language Press to confirm 8 4 6 4 Contrast Press into the Menu 6 Function Contrast Press or to adjust the Contrast from 1 6 Press to confirm The default number is 4 8 4 6 5 Default Press into the Men...

Страница 19: ...0 0 210 Glycerin 1900 0 075 Gold 3200 0 130 Ice 4000 0 160 Inconel 5700 0 220 Iron 5900 0 230 Iron cast 4600 0 180 Lead 2200 0 085 Magnesium 5800 0 230 Mercury 1400 0 057 Molybdenum 6300 0 250 Polythy...

Страница 20: ......

Страница 21: ......

Отзывы: