background image

Flight Manual DG-1000M 

Issued: July 2014  

TN1000/23 

 7.19 

Copyright DG Flugzeugbau GmbH - any copy or publishing prohibited

 

 
13.

 

"Raise Gear" = Landing gear should be retracted, appears 8 minutes after 
take-off in case the landing gear is still extended. 

14.

 

"Starter Run" = Starter motor didn’t disengage and is producing electric 
power, stop the engine immediately to prevent damage of the control unit. 
This message can't be erased by pushing the selector knob. 

15.

 

"CBox OvrTemp" = Starter motor control in control unit above temperature 
limit. If this warning appears don’t operate the starter motor any more. If 
possible switch off the main switch. 

16.

 

"Battery Overch." = Battery voltage constantly above 14,9V. 

17.

 

"Low Battery" = Battery voltage below 11V for more than 30 seconds. 

Caution:

 The starter motor control in the control unit will supply no electric 

power to the starter motor if the battery voltage is below 11 V prior to the 
starting attempt, starting is not possible! 

18.

 

"Main Switch" = Reminder to switch off the main switch.  
With landing gear retracted (e.g.on the trailer after derigging) after 60 
seconds.  
With landing gear extended (e.g. in the hangar) after 5 minutes.  
In both cases time counts after the last operation of any item of the 
electrical system. 

19.

 

Only with TNDG-G-09 executed:

 "Open Fuel! " = Fuel cock not fully 

opened. Warning appears when ignition will be switched on.  

7.4.5.3

 

Explanation for failure messages 

Spindle Fuse: 

The re-settable fuse for the spindle drive may be blown in the following 
cases: 

a) The propeller hub hooks during extension at the engine doors. 
b) The limit switch in position engine extended or retracted is not operated.  

As soon as the fuse is blown the Control Unit changes to manual extension-
retraction mode and thus cuts off power to the spindle drive and reports the 
failure to the DEI-NT.  
After the cool-down time (approx. 10sec.) the message disappears and the 
symbol for manual operation (hand) will be displayed on the screen.  
You may reactivate the automatic operation by operating the ignition 
switch, even during the cool-down time. 
Case a) Retract the powerplant again manually, then try to extend the 
engine again. 
Case b) Partially retract the engine manually and then try to extend the 
powerplant manually up to its operating position. 
 

Содержание DG-1000M

Страница 1: ...age will be indicated by a black vertical line in the right hand margin and the under lying document for the revision and the date will be shown on the bottom of the page Rev No Affected Pages section...

Страница 2: ...ctober 2010 October 2012 1 6 October 2010 2 EASA app 2 1 October 2010 2 2 October 2010 2 3 October 2010 2 4 October 2010 2 5 October 2010 October 2012 July 2014 2 6 October 2010 July 2014 2 7 October...

Страница 3: ...ctober 2012 4 16 October 2010 4 17 October 2010 4 18 October 2010 4 19 October 2010 4 20 October 2010 4 21 October 2010 October 2012 4 22 October 2010 4 23 October 2010 4 24 October 2010 October 2012...

Страница 4: ...2 6 13 October 2012 6 14 October 2012 6 15 October 2012 7 7 1 October 2010 7 2 October 2010 October 2012 7 3 October 2010 7 4 October 2010 7 5 October 2010 7 6 October 2010 October 2012 7 7 October 20...

Страница 5: ...ignition If you reduce the engine speed the ignition will be activated again Note The max engine RPM given by the engine manufacturer is 6700 RPM This max RPM is reduced for operation in the DG 1000M...

Страница 6: ...s Limitation data for the non useable amount of fuel printed above the display red 1 L When a fuel quantity of approx 4 Litres is reached a full screen warning Low Fuel appears when this warning has b...

Страница 7: ...Carry out a C G calculation according to section 6 9 The in flight C G will be moved forward by approx 75 mm 3 in depending on the flight mass and empty mass C G This C G shift is acceptable as the f...

Страница 8: ...retracted e g on the trailer after derigging after 60 seconds With landing gear extended e g in the hangar after 5 minutes In both cases time counts after the last operation of any item of the electri...

Страница 9: ...0 12 V min 12 Ah mass 5 5 kg 12 1 lbs is permitted The battery fuse is installed at the battery type G fuse G 250 V 5 x 20 4 A fast The wiring for this battery is in parallel to the battery in the bag...

Отзывы: