Terms and Definitions 

 

ORF 4

 — is the Telematics Service by  Technoton developed for  receiving and 

processing  Onboard  Reports  via  Internet,  displaying  Operational  Data  
overlapped  on  area

 

maps,  information  storage  in  database  and  Analytical  

Reports generation upon user’s request. 

 

S6

 — is the vehicle onboard data bus developed by 

TECHNOTON

 to enable 

integrating the GPS/GLONASS-based vehicle monitoring system into the 
vehicle electrical equipment. It comprises a set of cables, interfaces and 
protocols. Physically, it is implemented on the basis of  CAN 2.0B  
(ISO 11898-1:2003) and K-Line (ISO 9141). S6 bus data exchange protocol 
complies with SAE J1939 International Standard. 
To get more details on S6 telematics bus visit 

http://s6.jv-technoton.com/en/

 

PGN

 (Parameter Group Number) — is a combined group of S6 parameters, which has com-

mon  name  and  number.  Functional  Modules  (FM)  of  the  Unit  can  have  input/output  PGNs 
and setup PGNs. 

SPN

  (Suspect  Parameter  Number)  —  informational  unit  of  S6.  Each  SPN  has  determined 

name, number, extension, data type and numerical value. The following types of SPN exist: 
Parameters, Counters, Events. SPN can have a qualifier which allows qualification

 

of param-

eter’s value (e.g. – Onboard power supply limit/Minimum). 

Analytical report 

 

report generated in ORF4 on vehicle or group of vehicles operation for 

chosen time period (usually a day, week or month). Can be composed of numbers, tables, 
charts, mapped route of vehicle, diagrams. 

Onboard equipment 

(OE) — Telematics System Elements, directly installed in vehicle. 

Onboard Reports 

(the Reports) — iInformation about vehicle which is returned to a user of 

Telematics  System  in  accordance  with  inputted  criteria.  The  Reports  are  generated  by  a 
terminal unit both periodically (Periodic Reports) and on Event occurrence (Event Report). 

GNSS

  (Global  Navigation  Satellite  System)  —  System  for  area  positioning  of  an  object 

through satellite signal processing. GNSS is composed of space, ground and user segments. 
Currently, there are several GNSSs: GPS (USA), GLONASS (Russia), Galileo (EU), Compass 
(China). 

Online monitoring

 — remote monitoring of location and vehicle operation in real time, the  

accumulation  of  information  and  preparation  of  Analytical  Reports  by  requests  of  ORF  4  
user. 

Parameter

  —  vehicle’s  characteristics  varying  over  time  or  in  space.  E.g.  hourly  fuel  con-

sumption, speed, fuel volume in tank, coordinates. The Parameter is usually depicted as a 
chart and an average value.

 

Route 

—  data  massive,  consisting  of  coordinates,  speed  and  direction  of  vehicle’s  move-

ment. Corresponds to a real route of the vehicle. Depicted as lines on the Map. Direction of 
vehicle’s movement is depicted by arrows. 

Содержание DFM 100

Страница 1: ...L FLOW METERS DFM 50 100 250 500 one chamber and differential OPERATION MANUAL includes Service S6 DFM software manuals Version 6 4 This document is intended for fuel flow meters manufactured after 01 01 2016 ...

Страница 2: ... 2 Main specifications 23 1 6 3 Specifications of measuring chambers 25 1 6 4 Power supply modes 26 1 6 5 Operation modes 27 1 6 6 Displayed data 28 1 6 7 DFM protection from tampering and intervention 31 1 6 8 DFM pulse output signal specifications 32 1 6 9 RS 232 and RS 485 output interfaces specifications and protocol 33 1 6 10 CAN output interface specifications and protocol 34 1 7 DFM and tra...

Страница 3: ...g the tests 67 4 Accessories 69 4 1 Mounting kits 69 4 2 Connecting cables 74 4 3 Additional accessories 75 4 4 DFM DA 250 deaerator 77 5 Registered Events control 79 6 Diagnostics and troubleshooting 80 7 Verification 81 8 Maintenance 82 9 Packaging 83 10 Storage 84 11 Transportation 85 12 Utilization re cycling 86 Contacts 87 Annex A Overall dimensions and weight 88 Annex B Vehicle inspection re...

Страница 4: ...ion of flow meter available for order is added DFM 250 HP and DFM 500 HP charac terized by higher fuel consumption rate see Introduction figure 1 6 3 01 2017 OD DFM COM data transfer protocol updated see annex E table E 5 6 4 06 2017 OD Clarifications in DFM order identification codes added see Introduction figure 1 Table of measurement range and accuracy is divided in two separate parts for one c...

Страница 5: ...param eter s value e g Onboard power supply limit Minimum Analytical report report generated in ORF4 on vehicle or group of vehicles operation for chosen time period usually a day week or month Can be composed of numbers tables charts mapped route of vehicle diagrams Onboard equipment OE Telematics System Elements directly installed in vehicle Onboard Reports the Reports iInformation about vehicle...

Страница 6: ...numerical characteristics of Parameter Counter is represented by a number which can only grow in time Examples of Counters fuel consumption engine op eration time total distance and other Telematics system complex solution for real time and after trip vehicle monitoring and control Main vehicle parameters monitored route fuel consumption operation time tech nical condition of vehicle safety Consis...

Страница 7: ...otection against unauthorized interference in operation and data tampering maximum information richness of output data high reliability of data transmission over digital interfaces unique self diagnostics feature to monitor the stability and accuracy of data possibility of integration into on board Telematics Interface of vehicles embedded battery allows data Counters Events storage in the interna...

Страница 8: ...naccuracy is 0 5 Fuel flow meter DFM 500DK HP max flow rate 600 l h model differential without display output interface normalized pulse higher maximum consumption rate Fuel flow meter DFM 500CD max flow rate 500 l h model differential autonomous with display Fuel flow meter DFM 500CCAN max flow rate 500 l h model differential with display output interface CAN 2 0B A symbol is not specified for di...

Страница 9: ...oton com in Software Firmware category ATTENTION It is strongly recommended to follow strictly the instructions of the present Manual when using mounting or maintaining DFM The Manufacturer guarantees DFM compliance with the requirements of technical regulations subject to the conditions of storage transportation and operation set out in this Manual ATTENTION Manufacturer reserves the right to mod...

Страница 10: ...technical specifications 1 1 Purpose of use and application area flow meters are designed for fuel consumption measurement directly in fuel line of vehicles and stationary engines Figure 2 DFM puprose of application Application area DFM fuel flow meters are used both as a part of Telematics System and as a stand alone solution see figure 3 a within GPS GLONASS vehicle telematics system ...

Страница 11: ...er generates Analytical reports which allow time related Route control and Vehicle fuel consumption monitoring via web browser see Figure 4 DFM with pulse output interface provide data on actual fuel consumption of engine overall fuel consumption and average instant fuel consumption DFM with digital output interface provide real time control over extended set of infor mation instant fuel consumpti...

Страница 12: ...eceive data from up to 8 DUT E CAN sensors and up to 8 DFM CAN meters This possibility is especially useful while Vehicles with several engines river boats locomotives technological vehicles diesel genset stations are equipped Figure 4 Example of Analytical Report generated in ORF 4 sofware based on the DFM CAN data Use of DFM provides vehicle owners with the following actual fuel consumption reco...

Страница 13: ... pc 2 iButton key 1 pc 3 fuse with holder 2 A 1 pc 4 7 5m connection cable CABLE DFM 98 20 003 7 5 m 1 pc 5 Verification certificate 1 pc 6 Specification 1 pc Figure 5 DFM delivery set For DFM meters with built in display Not applicable for autonomous DFM fuel flow meters Only for DFM meters with pulse interface output 5 6 3 2 1 4 Download full version from Technoton Document center http docs jv t...

Отзывы: