Chapter 7 BIOS Setup
40
Console Redirection
Console redirection lets you monitor and control the system from a remote station by re-direct-
ing the host screen output through a serial port.
Console Serial Redirect
Enable or disable the console redirection function. (The default is disabled.) If you
select to enable it, please configure the following parameters for serial communica-
tion between the system and a remote station:
Terminal type: VT_100, , VT_UTF8, or PC_ANSI.
Baud rate: 115200, 57600, 38400, 19200, 9600, 4800, 2400 or 1200.
Data bits: 8 bits or 7 bits.
Parity: None, Even or Odd.
Stop bits: 1 bit or 2 bits.
Flow control: None, RTS/CTS or XON/XOFF
This is the global setting for all of the designated serial ports for the console redirec-
tion function.
COM1 to COM6
Enable or disable the serial redirection function for each of the serial ports on the sys-
tem. And configure the serial communication parameters to be used between the system
and a remote station.
UseGlobalSetting
Choose to use the pre-configured global settings from the previous menu or configure a
different setting for each serial port.